GENERAL SAFETY

INFORMATION

PRECAUTIONS

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN 

UNDER WATER.  Immediately call a qualified service technician 

to inspect the appliance and to replace any part of the control 

system and any gas control which has been under water.

IF THE  UNIT  IS  EXPOSED TO THE  FOLLOWING,  DO  NOT 

OPERATE HEATER UNTIL ALL CORRECTIVE STEPS HAVE 

BEEN MADE BY A QUALIFIED SERVICEMAN.

1.  EXTERNAL FIRE.

2. DAMAGE.

3.  FIRING WITHOUT WATER.

4.  SOOTING

CHEMICAL VAPOR CORROSION

 WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY 

OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN 

CHEMICAL VAPORS.  SUCH CORROSION MAY RESULT IN 

FAILURE AND RISK OF ASPHYXIATION.

Spray can propellants, cleaning solvents, refrigerator and air 

conditioning  refrigerants,  swimming  pool  chemicals,  calcium 

and sodium chloride (water softener salt), waxes, and process 

chemicals are typical compounds which are potentially corrosive. 

Do not store products of this sort near the heater.  Also, air which 

is brought in contact with a the heater should not contain any 

of these chemicals. If necessary, uncontaminated air should be 

obtained from remote or outside sources. The limited warranty 

is  voided  when  failure  of  water  heater  is  due  to  a  corrosive 

atmosphere.  (Refer to the limited warranty for complete terms 

and conditions.) 

IMPROPER COMBUSTION

WARNING

ATTIC AND/OR EXHAUST FANS OPERATING ON THE 

PREMISES WITH A WATER HEATER CAN RESULT IN CARBON 

MONOXIDE POISONING AND DEATH.

OPERATION OF THESE FANS CAN PRODUCE A NEGATIVE 

DRAFT IN THE AREA OF THE WATER HEATER PREVENTING 

THE PRODUCTS OF COMBUSTION FROM EXHAUSTING 

THROUGH THE CHIMNEY OR VENT PIPE.

The venting of the water heater should be inspected by a qualified 

service  technician  at  the  time  of  installation  and  periodically 

thereafter to ensure a down-draft condition does not exist.

DO  NOT  OBSTRUCT  THE  FLOW  OF  COMBUSTION AND 

VENTILATING AIR.  ADEQUATE AIR FOR COMBUSTION AND 

VENTILATION MUST BE PROVIDED FOR SAFE OPERATION.

LIQUID PETROLEUM MODELS

Water heaters for propane or liquefied petroleum gas (LPG) are

 

different from natural gas models.  A natural gas heater will not 

function safely on LP gas and no attempt should be  made to 

convert a heater from natural gas to LP gas.

LP gas must be used with great caution.  It is highly explosive

 

and heavier than air.  It collects first in the low areas making its 

odor difficult to detect at nose level.  If LP gas is present or even 

suspected, do not attempt to find the cause yourself.  Go to a 

neighbor’s house, leaving your doors open to ventilate the house, 

then call your gas supplier or service agent.  Keep area clear until 

a service call has been made.

At times you may not be able to smell an LP gas leak.  One cause 

is odor fade, which is a loss of the chemical odorant that gives 

LP gas its distinctive smell.  Another cause can be your physical 

condition, such as having a cold or diminishing sense of smell 

with age.  For these reasons, the use of a propane gas detector 

is recommended.

IF YOU EXPERIENCE AN OUT-OF-GAS SITUATION, DO 

NOT TRY TO RELIGHT APPLIANCES YOURSELF, 

Ask your 

LP  delivery  person  to  relight  pilots  for  you.    Only  trained  LP 

professionals  should  conduct  the  required  safety  checks  in 

accordance with industry standards.

EXTENDED NON-USE PERIODS

 WARNING

HYDROGEN  GAS  CAN  BE  PRODUCED  IN A  HOT  WATER 

SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN

 

USED  FOR A  LONG  PERIOD  OF TIME  (GENERALLY TWO 

WEEKS  OR  MORE).    HYDROGEN  GAS  IS  EXTREMELY 

FLAMMABLE. 

 To reduce the risk of injury under these conditions, 

it is recommended that the hot water faucet be opened for several 

minutes at the kitchen sink before using any electrical appliance 

connected to the hot water system.  If hydrogen is present, there 

will probably be an unusual sound such as air escaping through 

the pipe as the water begins to flow.  

THERE SHOULD BE NO 

SMOKING OR OPEN FLAME NEAR THE FAUCET AT THE TIME 

IT IS OPEN.

INSULATION BLANKETS

Insulation  blankets  available  to  the  general  public  for  external 

use  on  gas  water  heaters  are  not  approved  for  use  on  your 

Lochinvar water heater. The purpose of an insulation blanket is 

to reduce the standby heat loss encountered with storage tank 

water heaters. Your Lochinvar water heater meets or exceeds 

the current edition of ANSI/ASHRAE/IESNA Standard 90.1 with 

respect  to insulation  and  standby  loss  requirement  making  an 

insulation blanket unnecessary.

 

WARNING

Should you choose to apply an insulation blanket to this heater, 

you  should  follow  these  instructions.    Failure  to  follow  these 

instructions  can  result  in  fire,  asphyxiation  ,  serious  personal 

injury or death.

• 

  Do not

 apply insulation to the top of the water heater, as this

 

will interfere with safe operation of drafthood.

  Do not

  cover  the  gas  valve  or  temperature  &  pressure 

 

relief valve.

Содержание CG 120 THRU 400A

Страница 1: ...E CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE Thank you for buying this energy efficient wate...

Страница 2: ...58 kW Hr 379 L 183 cm 12 cm 165 cm 142 cm 50 cm 58 cm 1 2 143 cm 15 cm 77 cm 1 50 2 00 2 00 1 50 2 00 2 00 286 Kg 329 Kg CG N L 250 000 BTR Hr 100 Gal 72 00 4 50 65 13 55 87 19 75 23 1 2 56 38 8 30 2...

Страница 3: ...1745 1393 1162 996 871 776 697 632 583 538 500 CG N L 199 000 BTUH 100 Gal 80 643 482 386 322 276 241 214 193 175 161 148 132 199100 A 58 Kw Hr 379 L 2434 1825 1461 1219 1045 912 810 731 662 609 560...

Страница 4: ...bleshooting Guide 32 Operational Checklist 33 Limited Warranty 34 Page Page FOREWORD These designs comply withANSI Z21 10 3 CSA4 3 as an automatic circulating or automatic storage tank type water heat...

Страница 5: ...ve and heavier than air It collects first in the low areas making its odor difficult to detect at nose level If LP gas is present or even suspected do not attempt to find the cause yourself Go to a ne...

Страница 6: ...nt with orifices sized for the particular installation elevation Correct orifice sizing and parts may be obtained from Lochinvar LLC When ordering be sure to state the model number and the altitude of...

Страница 7: ...TION and HOLD OPEN DAMPER For normal operation the switch should be in the AUTOMATIC OPERATION position If there is a problem with the damper the Service Switch can be placed in the HOLD OPEN DAMPER p...

Страница 8: ...n on combustible flooring in an alcove when the minimum clearance from any combustion construction are followed as indicated in figure 6 and Table 2 The National Sanitation Foundation also recommends...

Страница 9: ...ee MAINTENANCE section for details of tank cleanout procedure AIR REQUIREMENTS REFER TO THE CURRENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 FOR CANADA CONSULT NATURAL GAS AND PROPANE...

Страница 10: ...AND ASPHYXIATION Heater must be protected from freezing downdrafts Remove all soot or other obstructions from the chimney that will retard a free draft Type B venting is recommended with these heater...

Страница 11: ...CG N L 180080 200080 200100 199100 Input 180 000 190 000 199 000 Btuh Total Vent Height Feet Draft Hood 6 6 8 10 15 20 30 50 100 Input Btuh Rise Vent Connector Diameter in inches 180 000 1 Ft 8 8 8 8...

Страница 12: ...N L 305065 A Input 305 000 Btuh Total Vent Height Feet Draft Hood 8 6 8 10 15 20 30 50 100 Input Btuh Rise Vent Connector Diameter in inches 315 000 1 Ft 10 10 10 10 10 10 305 000 2 Ft 10 10 10 10 10...

Страница 13: ...tank which may be used in conjunction with this appliance shall also be installed with a properly sized rated and approved combination temperature ANSI and pressure ASME relief valve s WARNING THE PU...

Страница 14: ...F THE GAS SUPPLY SYSTEM NOT THE HEATER VENT BLOCKAGE MAY OCCUR DURING ICE STORMS IT IS IMPORTANT TO GUARD AGAINST GAS VALVE FOULING FROM CONTAMINANTS IN THE GAS WAYS SUCH FOULING MAY CAUSE IMPROPER OP...

Страница 15: ...UPPLY PRESSURE TESTING EXCEEDING 1 2 PSIG 3 5 kPa GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER FOR TEST PRESSURES OF 1 2 PSIG 3 5 kPa OR LESS THE APPLIANCE NEED NOT BE DISCONNECTED...

Страница 16: ...ULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROLWARNING ON PAGE 27 IF HIGHER PREHEATTEMPERATURESARE NECESSARY TO OBTAINADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR...

Страница 17: ...T BE CLOSED ON DURING THERINSEOPERATIONANDOPEN OFF WHENDISHWASHER IS NOT OPERATING OR WHEN ON LONG STANDBY NOTE 2 INSTALL LINE TEMPERATURE CONTROL IN AN UNINSULATED TEE BEYOND THE DISHWASHING MACHINE...

Страница 18: ...n the installation diagrams on the following pages are typical TWO TEMPERATURE TWO HEATERS ONE PRE HEATER ONE BOOSTER HEATER WITH OR WITHOUT BUILDING RECIRCULATION The discharge opening of the tempera...

Страница 19: ...3 ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW RATE DOES NOT CAUSE UNNECESSARY TURBULENCE IN THE TANK PIPE RELIEF VALVE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH LOCAL CODES CIRCULATING RETURN LINE CO...

Страница 20: ...WITH MIXING VALVE TWO PRE HEATERS WITH BOOSTER HEATER DANGER TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 27 IF HIGHER PREHEAT T...

Страница 21: ...TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES PIPE RELIEF VALVE TO OPEN DRAIN IF BUILDING CIRCULATING LOOP IS USED CONNECT TO...

Страница 22: ...uctions MULTIPLE UNIT INSTALLATIONS For multiple unit installations contact Lochinvar Parts Department 300 Maddox Simpson Pkwy Lebanon TN 37090 Phone 615 889 8900 Fax 615 882 2918 email parts_team loc...

Страница 23: ...AVOIDRISKOF FIRE OR EXPLOSION PURGE DISCHARGE MUST NOT ENTER CONFINEDAREAS OR SPACES WHERE IGNITION CAN OCCUR THEAREAMUSTBE WELLVENTILATEDANDALLSOURCES OF IGNITION MUST BE INACTIVATED OR REMOVED WARNI...

Страница 24: ...24 FOR NATURAL GAS MODELS FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING...

Страница 25: ...25 FOR PROPANE GAS MODELS FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE...

Страница 26: ...hority The water temperature is controlled by a thermostat Fig 3 which has two sensing elements One sensor is located near the top of the tank and the other is near the center The thermostat is set in...

Страница 27: ...combustion PREVENTIVE MAINTENANCE CHECK THE PILOT At least once a year check the pilot burner fig 15 and the main burner fig 16 for proper operation Refer to the following pilot and main burner sectio...

Страница 28: ...a pressure gauge or a manometer to the gauge port and refer to Table 5 for correct manifold pressure 2 Use this formula to clock the meter Be sure that other gas consuming appliances are not operating...

Страница 29: ...ther information contact your dealer ANODE ROD INSPECTION The heater tank is equipped with anode rods to provide corrosion control At least once a year the anode rods should be checked to determine if...

Страница 30: ...g screws securely 7 Replace outer jacket cover plate In some water areas the sediment might not be removed by this method and may result in the water heater making rumbling or boiling noises To dissol...

Страница 31: ...xt trial for ignition check gas supply pilot burner spark and flame sense wiring flame rod contaminated or out of position burner ground connection 3 Recycle Flame failed during run Initiate new trial...

Страница 32: ...n fuse or circuit breaker 5 Disconnect switch off 6 Harness not plugged into appliance receptacle A FLUE DAMPER OPEN OR OPENING Unit is calling for heat and damper disc should be in vertical position...

Страница 33: ...s slower Call service agent Check gas input If incorrect adjust gas pressure or replace main burner orifice Draft hood not installed or Call service agent Install draft hood or baffles as one or more...

Страница 34: ...so installed at the heater s and operational at all times The temperature and pressure relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited...

Страница 35: ...35 NOTES...

Страница 36: ...36 Copyright 2011 Lochinvar LLC All rights reserved 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Service email 2tech lochinvar com www Lochinvar com...

Отзывы: