LNC-T800
LNC Controller Operation Instruction
LNC Technology Co., Ltd.
95
2.11 Parameter Setting
The method of parameter setting is as the following:
1. Make sure machine is currently in the status of preparation done.
2. Switch to <PARAM> group.
3. Click
【
NC.SYS
】
function button to switch to parameter screen.
4. Use Up, Down, Right, Let buttons to move cursor to the parameter to be set. If the serial number of the
parameter to be edit is known, input Pxxxx in input line, and click INPUT button to position to the
parameter. The xxxx represents the serial number of the parameter.
5. After moving to the parameter, input desired values in input line, and click <INPUT>.
6. A box asking for a password appears. Input correct password to proceed to parameter modification.
7. Default value of password is 0000. The password can be changed. Please well remember the changed
password, if not, parameters will not be able to be changed.
2.12 Backup System Parameters
It is recommended to backup machine setting parameters after machine adjustment is done. The method to
backup parameters is as the following:
1. Prepare an empty disk, make sure it’s not write-protected, and scan it for virus at first. Insert it to FDD.
2. Click emergent stop to let machine enter the NO-RDY status.
3. Switch to <DGNOS> group.
4. Click
【
SUSUPD
】
function button to switch to system upgrade operation screen.
5. Use UP, Down buttons to move cursor to PARAM BACKUP position, and click
【
OK
】
button.
6. Click
【
ALL
】
function button to select all parameter categories and click
【
OK
】
button.
7. Use UP, Down buttons to move cursor to GENERAL DISK/NET Method and click
【
OK
】
button.
8. Clear the displayed folder path, and input A:\. Click
【OK】
button to start backup parameters. When the
backup is done, a prompt appears in prompt line.
Содержание LNC-T800
Страница 2: ......