READ
】
:
Read part programs transmitted from external PC to controller by RS232.
【
SAVE
】
:
Save received part program. Part program transmitted to controller are not saved after the
transmission, users have to manually save the programs. Click Save function button, and the
following screen appears, select the save path and file namem and then click
【
OK
】
button finish
the process of saving file.
Figure 1.4-38 Save file function screen
【
CLEAR
】
:
Give up and clear program files on screen. If the received data are not correct, click this function
button to reset transmission status of the hardware.
【
SETT
】
Settings of RS232 must be correct and compatible with PC in order to successfully proceed RS232
transmission. Adjust with the following parameters:
Parameter Serial Number
Name
P0388
File Transmission Port (0:not use, 1:COM1, 2:COM2)
P0389 File
Transmission
Rate
(bps)
P0390
File Transmission Data Bit (5~8 bit)
P0391
File Transmission Stop Bit (0:1 bit,1:1. 5 or 2bit)
P0392
File Transmission Parity Check Bit (0:not ust, 1:odd, 2:even)
P0393 File
Transmission
Code (0:ASCII, 1:EIA, 2:ISO)
Содержание LNC-T800