22/92
3.4.
Sound power level
WARNING
Danger of hearing damage
As from a sound power level of 85 dB (A), wearing hearing protection is mandatory.
Wear your personal hearing protection.
The detail defines the volume of the noise relative to the operator's workplace and to the sound power
level of the floor saw.
The measured sound power level L
wA
108 dB(A)
The emission sound power level at the operator's workplace L
pA
89 dB(A)
The guaranteed sound power level is:
UC 520
109 dB(A)
The values are found by measuring the sound emissions.
The test was carried out on the largest approved saw blade of the floor saw under load.
Measurement tolerances:
2.5 dB for the A-weighted sound power level
4 dB for the A-weighted emission sound power level
The emission sound power level was measured in consideration of the
EN ISO 3744 and EN 13862 standards and the 2000/14/EC Directive.
3.5.
Exhaust fumes
DANGER
Poisonous exhaust gases
The exhaust gases of the internal combustion engine contain carbon monoxide. It is invisible, odorless and
tasteless, and can cause suffocation. It can quickly accumulate in narrow spaces and stay there for hours,
even after the engine has been turned off
Never operate machines with internal combustion engines in closed or confined spaces
If you feel dizzy or uneasy, turn off the engine immediately. Visit a doctor. You may suffer from
carbon monoxide poisoning.
Exhaust pipe
Depending on the seating position, the exhaust
system may be unfavorable for the operator.
The outlet of the exhaust pipe must always point
away from the operator. Do not inhale exhaust
fumes.
The exhaust pipe may get hot during operation.
Avoid contact and wear protective equipment.