During your dive, the KAON will begin by displaying your No Decompression Limit (NDL). If you
complete your dive within the NDL time, the KAON will tell you to complete a safety stop for 3
minutes at 5m/15ft. During these 3 minutes, if you drop below 6.5m/21ft, the safety stop counter will
turn off and reset. It will begin again once you return to the safety stop depth of 5m/ 15ft.
Should you continue diving beyond your NDL time –
and you should only do this if you have
knowledge of decompression diving and sufficient gas to complete the dive safely
- the KAON will
start calculating your decompression obligation and indicate the depth and duration of any
decompression stops you need to complete to exit the water safely. The unit calculates your NDL or
your decompression plan using Bühlmann ZH-L16C
, with one of three possible levels conservatism
(please see the
section of the manual for more information)
Gauge Mode
In Gauge mode, the KAON acts as a bottom timer and provides information on dive depth and time. It
does not keep track of your No Decompression Limit, decompression obligations or tissue saturation.
IMPORTANT NOTE ON SWITCHING TO/FROM GAUGE MODE
In Gauge Mode, surface off-gassing continues when the device is above
water. Once the device is underwater, all deco calculations are suspended.
When switching from Gauge Mode to Rec/Tec Mode, the deco information
will no longer be accurate, since previous tissue values are used.
When you switch out of Gauge Mode, you will see this warning:
Tap Left to continue.
Here is an example of a situation where this warning may arise:
Dive 1
: KAON in Rec or Tec mode, switch to Gauge mode
Surface interval – KAON continues to track your post-Dive 1 tissue saturation
Dive 2
: KAON in Gauge mode. KAON stops tracking your post-Dive 1 tissue saturation.
Surface interval
Dive 3
: KAON In Rec or Tec mode. KAON tissue saturation values are wrong!!! KAON reverts to
post-Dive 1 tissue saturation values that were valid at the moment you started Dive 2. It does not
account for the ongoing desaturation from Dive 1, not for the added saturation of Dive 2.
4.2. Dive Setup (only in Tec Mode)
Your KAON calculates No Decompression Limits (NDLs) or your decompression times based on the
proven Bühlmann ZH-L16C
4.2.1. Conservatism
algorithm. This menu item allows you to add conservatism to the KAON
decompression calculations using three pre-set levels:
Level “0” - standard Bühlmann ZH-L16C with no added conservatism (Gradient Factors 100/100)
Level “1” - Bühlmann ZH-L16C with some added conservatism (Gradient Factors 30/85)
Level “2” - Bühlmann ZH-L16C with more added conservatism (Gradient Factors 30/75)