21
valves
Solenoid 1 Wiring for
Single Stage Valves
Earth/
Green
(16)
Out7/
Black
(15)
+12V/
Black
(14)
84040 Board
SOLENOIDS J13
Jumper from
Terminal 15
to Terminal 18
S1&2
Solenoid 1 and Solenoid 2 Wiring for A2859-11
and 3-Way Two Stage, 2848-11 Two Stage,
E7 Two Stage Wiring
Connector
Block S2
Connector
Block S1
84040 Board
SOLENOIDS J13
Earth/Green (16)
Earth/Green (16)
Earth/Green (19)
Earth/Green (19)
Out7/Black (15)
Out7/Black (15)
Out6/Black (18)
Out6/Black (18)
+12V/Black (14)
+12V/Black (14)
+12V/Black (17)
+12V/Black (17)
2
1
2
1
valve Installation
If installing the valve yourself, please refer to the valve’s
installation and operation manual for mechanical
installation. Instructions for wiring Liquid Controls valves
to the LCR-II are on the following two pages.
Materials needed for wiring valves:
not supplied
with the valve
•
20 AWG stranded wire (3 per solenoid).
Not necessary for
3-Way solenoid valves. Only 2 needed for E7 solenoids.
•
Weatherproof flexible conduit, ½" diameter and ½" NPT
conduit connectors or cable glands
•
PTFE tape or pipe sealant
To wire valves to the lCr-II:
1. Attach cable glands and/or conduit connectors to the
solenoid valve(s) and the LCR-II port(s).
2. Thread the wires through piece of weatherproof conduit
that is cut-to-length from the solenoid to a LCR-II port.
3. Run the weatherproof conduit between the solenoid-
operated valve(s) and the LCR-II housing, pull the wires
through the ports, and tighten the connectors.
4. Connect the S1 solenoid-operated valve wires to
terminals 14 and 15 on the j13 terminal block of the LCR-
II CPU board.
5. Connect the S2 solenoid-operated valve wires to
terminals 17 and 18 on the j13 terminal block of the LCR-
II CPU board.
To wire a single stage valves for presetting:
1. Wire the S1 solenoid as instructed above.
2. Run a jumper wire from Terminal 15 to Terminal 18.
Disconnect the power before working on the CPU board.
Disconnect Power
Solenoid operated valve 81527 (3-way LPG solenoid)
has 3 cables potted into the housing. All other
solenoid operated valves on Liquid Controls valves
use cable assembly 81859, which has 2 cables.
Solenoid Operated Valve Cables
The Earth grounds for Terminals 16 & 19 are optional.
The solenoid operated valves are grounded through
the component they are mounted on.
Earth Grounds for Solenoid Valves