7.4 Monitoring
All drive series support enhanced monitoring features of the supply voltages and the board
temperatures.
7.4.1 Logic Supply Voltage
The logic supply voltage must be in the range from 20V to 28V when using the default
parameter settings. If the supply voltage goes out of this range, an error will be generated. If
the supply voltage goes below approx. 18V the drive shuts down.
Parameter Name
UPID
Description
Logic Supply
Voltage Too Low
100Eh
If the logic supply voltage sinks below this limit the error 01h
will be generated.
Parameter Name
UPID
Description
Logic Supply
Voltage Too High
1010h
If the logic supply voltage rises above this limit the error 02h
will be generated.
7.4.2 Motor Supply Voltage
The motor supply voltage can be monitored with different warn and error levels.
Parameter Name
UPID
Description
Motor Supply
Voltage Low
1018h
If the motor supply voltage sinks below this limit the warn bit
Motor Supply Voltage Low (bit 2) is set.
Motor Supply
Voltage High
1019h
If the logic supply voltage rises above this limit the warn bit
Motor Supply Voltage High (bit 3) is set.
Parameter Name
UPID
Description
Motor Supply
Voltage Too Low
101Ah
If the logic supply voltage sinks below this limit the error 03h
will be generated.
Motor Supply
Voltage Too High
101Bh
If the logic supply voltage rises above this limit the error 04h
will be generated.
7.4.2.1 Phase Switch On Test
The parameters in the Phase Switch On Test section are used in the HW Tests State (State
5) before enabling the power stage. If the motor power supply is on and there is no ground
path in the motor (inclusive cabling) the phase voltage is approx. 6.5V when in power off
state. When moving the motor the induced voltage may lead to HW test error.
Parameter Name
UPID
Description
Phase Voltage
Low Level
102Ch
If one of the phase voltages is below this limit before
powering up an error will be generated.
Phase Voltage
High Level
102Dh
If one of the phase voltages is above this limit before
powering up an error will be generated.