Motion Control SW
L
i
n
M
o
t
4.3.15
VAI Stop (017xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
017xh: VAI Stop
UInt16 -
1. Par
2
Deceleration
UInt32 1E-5 m/s
2
4.3.16
VAI Go To Pos After Actual Command (018xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
018xh: VAI Go To Pos After Actual Command
UInt16 -
1. Par
2
Target Position
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration
UInt32 1E-5 m/s
2
4. Par
14
Deceleration
UInt32 1E-5 m/s
2
This command waits until the actual motion setpoint generation has finished, then starts the
new defined VAI motion.
4.3.17
VAI Go To Analog Pos (019xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
019xh: VAI Go To Analog Pos
UInt16
-
1. Par
2
Maximal Velocity
UInt32
1E-6 m/s
2. Par
6
Acceleration
UInt32
1E-5 m/s
2
3. Par
10
Deceleration
UInt32
1E-5 m/s
2
4.3.18
VAI Go To Pos On Rising Trigger Event (01Axh)
Name
Byte
Offset
Description
Type
Unit
Header
0
01Axh: VAI Go To Pos On Rising Trigger Event
UInt16 -
1. Par
2
Target Position
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration
UInt32 1E-5 m/s
2
4. Par
14
Deceleration
UInt32 1E-5 m/s
2
4.3.19
VAI Increment Target Pos On Rising Trigger Event (01Bxh)
Name
Byte
Offset
Description
Type
Unit
Header
0
01Bxh: VAI Increment Target Pos On Rising Trigger
Event
UInt16 -
1. Par
2
Position Increment
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration
UInt32 1E-5 m/s
2
4. Par
14
Deceleration
UInt32 1E-5 m/s
2
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013
Page 29/91