L
i
n
M
o
t
Motion Control SW
4.3.195
VAI Go To Pos From Act Pos And Reset Force Control
(381xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
381xh: VAI Go To Pos From Act Pos And Reset
Force Control
UInt16
-
1. Par
2
Target Position
SInt32
0.1 um
2. Par
6
Maximal Velocity
UInt32
1E-6 m/s
3. Par
10
Acceleration
UInt32
1E-5 m/s
2
4. Par
14
Deceleration
UInt32
1E-5 m/s
2
Reinstalls the position control mode and moves to the defined target position.
4.3.196
Force Ctrl Change Target Force (382xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
382xh: Force Ctrl Change Target Force
UInt16
-
1. Par
2
Target Force
Sint16
0.1 N
This command can be used to change the target force during the force control mode.
4.3.197
VAI Go To Pos With Higher Force Ctrl Limit and Target Force
(383xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
383xh: VAI Go To Pos With Higher Force Ctrl Limit
and Target Force
UInt16
-
1. Par
2
Target Position
Sint32
0.1 um
2. Par
6
Maximal Velocity
UInt32
1E-6 m/s
3. Par
10
Acceleration
UInt32
1E-5 m/s
2
4. Par
14
Force Limit
Sint16
0.1 N
5. Par
16
Target Force
Sint16
0.1 N
Moves to the defined target position, if the measured force reaches the higher force limit the
drive switches to the force control mode with target force = target force.
To change back to position control mode use motion command VAI Go To Pos From Act Pos
And Reset Force Control (381xh).
4.3.198
VAI Go To Pos With Lower Force Ctrl Limit (384xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
384xh: VAI Go To Pos With Lower Force Ctrl Limit
UInt16
-
1. Par
2
Target Position
SInt32
0.1 um
2. Par
6
Maximal Velocity
UInt32
1E-6 m/s
3. Par
10
Acceleration
UInt32
1E-5 m/s
2
4. Par
14
Force Limit
Sint16
0.1 N
Moves to the defined target position, if the measured force reaches the lower defined value
the drive switches to the force control mode with target force = force limit.
To change back to position control mode use motion command VAI Go To Pos From Act Pos
And Reset Force Control (381xh).
Page 64/91
User Manual Motion Control SW / 06/12/2013
NTI AG / LinMot