Motion Control SW
L
i
n
M
o
t
This command starts a new VAI setpoint generation from the actual position and actual
velocity. Can be used after a press command.
4.3.109
VAI Dec=Acc Go To Pos From Act Pos Starting With Dem Vel
= 0 (0C4xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0C4xh: VAI Dec=Acc Go To Pos From Act Pos
Starting With Dem Vel =0
UInt16 -
1. Par
2
Target Position
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration = Deceleration
UInt32 1E-5 m/s
2
This command starts a new VAI setpoint generation from the actual position and the start
velocity is forced to zero. Can be used after a press command.
4.3.110
VAI Dec=Acc Go To Pos With Max Curr (0C5xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0C5xh: VAI Dec=Acc Go To Pos With Max Curr
UInt16 -
1. Par
2
Target Position
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration = Deceleration
UInt32 1E-5 m/s
2
4. Par
14
Demand Curr Limit
Uint16 1mA
This command can be used as press command with limited current (force). This command
sets the maximal current of the actual position controller set (UPID 13A6h or 13Bah) to the
value defined with the 4
th
parameter. To reset the current to the normal value, use the
command 0C6xh or 0C7xh.
4.3.111
VAI Dec=Acc Go To Pos From Act Pos And Vel With Max Curr
(0C6xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0C6xh: VAI Dec=Acc Go To Pos From Act Pos And
Vel With Max Curr
UInt16 -
1. Par
2
Target Position
SInt32 0.1 um
2. Par
6
Maximal Velocity
UInt32 1E-6 m/s
3. Par
10
Acceleration = Deceleration
UInt32 1E-5 m/s
2
4. Par
14
Demand Curr Limit
Uint16 1mA
This command can be used after the command 0C5xh to set the current to the normal value.
At the beginning of the motion the position controller integrator is cleared. This command
sets the maximal current of the actual position controller set (UPID 13A6h or 13BAh) to the
value defined with the 4
th
parameter.
4.3.112
VAI Dec=Acc Go To Pos From Act Pos And Vel = 0 With Max
Curr (0C7xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0C7xh: VAI Dec=Acc Go To Pos From Act Pos And UInt16 -
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013
Page 49/91