Motion Control SW
L
i
n
M
o
t
7.2.1.3 X4.3 Brake Operation Quick Stop Behavior
If also the Quick Stop brake behavior is selected the brake is applied (X4.3 = 0V) as soon as
the motion has stopped, then the reset of the Operation Enabled bit is delayed by the apply
delay time, which then also powers off the motor.
Parameter Name
UPID
Description
Apply
Delay
Time
171Bh
Delay time of the Status Word bit: Operation Enabled after
the motion has stopped.
7.2.2 X4.6 Trigger
For the trigger input, which is evaluated in the motion control task, different evaluation modes
are supported.
Parameter Name
UPID
Description
Trigger Modes
170Ch
Trigger mode selection:
•
0: None
•
1: Direct
•
2: Inhibited
•
3: Delayed
•
4: Inhibited & Delayed
7.2.2.1 Direct Trigger Mode
In the Direct Trigger Mode copies the trigger input directly copied to the trigger output, which
is used by the MC-SW. No parameter configuration is needed for this mode.
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013
Page 73/91
Trigger In
Trigger Out
Operation Enabled
Brake Out X4.3
/Quick Stop
Stopping
Apply Delay Time