3.23Status Word
Following table shows the meaning of the single bits:
¬
Bit
Name
Val Meaning
Remark
0
Operation Enabled
0
State Nr < 8
1
Operation Enabled
State Nr 8 or higher (copied to drive EN LED )
1
Switch On Active
0
Switch On Disabled
Control Word Bit 0
1
Switch On Enabled
2
Enable Operation
0
Operation Disabled
Control Word Bit 3
1
Operation
3
Error
0
No Error
1
Error
Acknowledge with Control word Bit 7 (Reset Error)
4
Voltage Enable
0
Power Bridge Off
Control Word Bit 1
1
Operation
5
/Quick Stop
0
Active
Control Word Bit 2
1
Operation
6
Switch On Locked
0
Not Locked
1
Switch On Locked
Release with 0 of Control word bit 0 (Switch On)
7
Warning
0
Warning not active
No bit is set in the Warn Word
1
Warning active
One or more bits in the Warn Word are set
8
Event Handler Active
0
Event Handler Inactive
Event Handler cleared or disabled
1
Event Handler Active
Event Handler setup
9
Special Motion Active
0
Normal Operation
1
Special Command runs
Special motion commands (Homing, ..) runs
10
In Target Position
0
Not In Pos
Motion active or actual position out of window
1
In Pos
Actual position after motion in window
11
Homed
0
Motor not homed
Incremental sensor not homed (referenced)
1
Motor homed
Position sensor system valid
12
Fatal Error
0
1
Fatal Error
A fatal error cannot be acknowledged!
13
Motion Active
0
No Motion
Setpoint generation inactive
1
Motion active
Setpoint generation (VAI, curve) active
14
Range Indicator 1
0
Not In Range 1
Defined UPID is not in Range 1
1
In Range1
Defined UPID is in Range 1
15
Range Indicator 2
0
Not In Range 2
Defined UPID is not in Range 2
1
In Range2
Defined UPID is in Range 2
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013