L
i
n
M
o
t
Motion Control SW
1. Par
2
Curve ID
UInt16
1..100
2. Par
4
Curve Start Count
SInt32
1 Incr
3. Par
8
Start Position
SInt32
0.1 um
4. Par
12
Target Position
SInt32
0.1 um
5. Par
16
CAM Length In Counts
SInt32
1 Incr
4.3.134
Encoder Cam y Define Curve To Pos In Counts (1y4xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
1y4xh: Encoder Cam y Define Curve To Pos
(y=1..2)
UInt16
-
1. Par
2
Curve ID
UInt16
1..100
2. Par
4
Curve Start Count
SInt32
1 Incr
3. Par
8
Target Position
SInt32
0.1 um
4. Par
12
CAM Length In Counts
SInt32
1 Incr
If the encoder value is in the range of cam y, the motor has to be at the start position of the
cam y during command setup, to set the position start point correctly of cam y.
4.3.135
Encoder Cam y Define Curve With Amplitude Scale In Counts
(1y5xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
1y5xh: Encoder CAM y Define Curve To Pos
(y=1..2)
Uint16
-
1. Par
2
Curve ID
Uint16
1..100
2. Par
4
Curve Start Count
Sint32
1 Incr
3. Par
8
Amplitude Scale
Sint16
0.1%
4. Par
10
CAM Length In Counts
Sint32
1 Incr.
The values for the amplitude scale and cam length are updated immediately, for this reason
this command should only used outside the cam y (old and new) definition. For changing the
amplitude scale and/or length during cam y is active, use the command 1y8xh instead.
4.3.136
Encoder Cam y Enable (1y6xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
1y6xh Encoder Cam y Enable; (y=1..2)
Uint16
-
4.3.137
Encoder Cam y Disable (1y7xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
1y7xh Encoder Cam y Disable; (y=1..2)
Uint16
-
4.3.138
Encoder Cam y Change Amplitude Scale and Length (1y8xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
1y8xh: Encoder Cam y Define Curve To Pos
(y=1..2)
Uint16
-
Page 54/91
User Manual Motion Control SW / 06/12/2013
NTI AG / LinMot