Document #: LIN_EO_SM_IMPAPERION2424_4607818 – 07/21
17
Section 2
Installation
Installation Checklist
DANGER
Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
n
Warning
On completion of any installation or service work, test
for gas leaks before returning the equipment into service.
Never use matches, candles, or any other ignition source
to check for leaks. If gas odors are detected, shut off the
gas supply to the appliance at the main shut-off valve
and immediately contact the local gas company or an
authorized service agency for service.
DO NOT ATTEMPT TO OPERATE THE OVEN until connection
of utility service and installation has been fully inspected
(START-UP CHECKOUT) by a Factory Authorized Servicer or
a Lincoln Foodservice Products, LLC Service Representative.
This service is required by Lincoln Foodservice Products,
LLC in order to insure the oven(s) is properly installed and
in working order. The warranty becomes effective upon
verification of proper installation.
The warranty shall not apply if the oven is started up
and operated prior to the “START-UP CHECKOUT” being
performed by a Factory Authorized Servicer or a Lincoln
Foodservice Products, LLC Service Representative.
CHECKLIST
Are the supplied rear bumpers installed to the rear cover
of the unit?
Are the correct clearances maintained?
Does the ventilation system meet the requirements?
Are the legs and caster securely fastened?
Is the unit level?
Has the restraint been installed to prevent uncontrolled
movement?
Have all electrical connections been made and the unit
is grounded?
Does each oven have a separate disconnect switch?
Have all wiring connections including the factory
connections been checked?
Has the supply voltage been tested and verified it
matches the name plate voltage?
Has a shutoff valve been installed in the gas line ahead
of the unit?
Has the manifold gas pressure been set to match the
rating on the nameplate?
Have all gas connections been tested for leaks?
Are the retaining brackets and finger assemblies
correctly installed and positioned?
Is the belt tension correct?
Have access panels been installed and secured?
Has a smoke candle test been performed?
Has the unit been tested for correct operation?
Has the owner been instructed in the correct operation
of the unit?
Has this manual been given to the store owner?
Содержание Impinger Aperion 2424E
Страница 44: ...44 Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 Notes ...
Страница 45: ...Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 45 Notes ...
Страница 46: ...46 Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 Notes ...
Страница 47: ...Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 47 Section 8 Diagrams THIS PAGE INTENTIONALLY LEFT BLANK ...