Document #: LIN_EO_SM_IMPAPERION2424_4607818 – 07/21
9
Section 2
Installation
Installation Requirements
DANGER
All utility connections and fixtures must be maintained in
accordance with local and national codes.
GAS CODE REQUIREMENTS
n
Warning
A manual shut-off valve must be installed in the gas
supply (service) line upstream of this appliance so that
the test plug is on the oven side of the valve.
Safe and satisfactory operation of this oven depends to a
great extent upon its proper installation, and it should be
installed, as applicable in accordance with the National
Fuel Gas Codes, ANSI Z223.1/NFPA 54, latest version,
manufacturers’ installation instructions, local municipal
building codes, and ISO 203-1.
1. The oven and its individual shut off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45 kPa).
2. The oven must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply system at
test pressures equal to or less than 1/2 psig (3.45 kPa).
IN MASSACHUSETTS: The minimum length of a flexible gas
supply hose is thirty-six (36") inches.
IN CANADA: The installation of these appliances is to be in
accordance with CSA B.149.1 latest version – Natural Gas and
Propane Installation Code – and/or local codes.
IN AUSTRALIA: To be installed in accordance with AS 5601-
2004 and 4563-2004 Gas Installation Code.
ELECTRICAL CODE REQUIREMENTS
n
Warning
This appliance must be properly grounded at time
of installation. Failure to ensure that this equipment
is properly grounded can result in electrocution,
dismemberment or fatal injury.
When installed, this appliance must be electrically grounded
and its installation must comply with the National Electric
Code, ANSI-NFPA 70, latest edition, the manufacturers’
installation instructions, and applicable local municipal
building codes.
IN CANADA: All electrical connections are to be made
in accordance with CSA C22.2 latest version – Canadian
Electrical Code and/or local codes.
ALL OTHER COUNTRIES: Local gas and/or electrical codes will
prevail.
1. Strain Relief is provided with each oven. International
Dealer/Distributors provide applicable power cord/plug
for each customer.
2. All pole disconnection switch must have 3 mm open
contact distance.
3. To prevent electrical shock, an equal potential bonding
ground lug is provided in the back. This allows the oven
to be connected to an external bonding system.
4. If used as double stack or triple stack
1
and each oven
has its own disconnection switch, all switches should be
close together.
1
2424 ventless ovens equipped with a catalyst(s) are
approved for single oven ventless operation.
Содержание Impinger Aperion 2424E
Страница 44: ...44 Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 Notes ...
Страница 45: ...Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 45 Notes ...
Страница 46: ...46 Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 Notes ...
Страница 47: ...Document LIN_EO_SM_IMPAPERION2424_4607818 07 21 47 Section 8 Diagrams THIS PAGE INTENTIONALLY LEFT BLANK ...