Parallel daisy chain network:
With the parallel system with the extra socket, there is the possibility to connect the actuator in daisy chain
connection.
Daisy chain, means the network can be connected in a line or a ring. In this case actuators are connected in
a daisy chain line. Meaning that the first and the last one are not connected together.
Communication in-between actuators is possible through the extra socket (3) combined with standard
signal socket (2).
Meaning socket 2 and 3 have to be used in order to connect the actuator in daisy chain line.
Inwards and outwards signal can only be applied to one actuator when they are connected in a daisy chain.
The EOS signals can also be read out from the same cable.
You can connect up to 8 actuators in a daisy chain.