![Linak TECHLINE LA33 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/linak/techline-la33/techline-la33_user-manual_1916970035.webp)
Page 35 of 76
Proportional (speed) control
With neutral in the middle, speed will vary
according to PWM duty cycle, extending and
retracting respectively.
Extending at full speed
Stop
Stop
Extend
Retract
Stop
Retracting at full speed
100% speed
100% speed
25% speed
25% speed
95%
90%
55%
45%
10%
5%
•
Current cut-offs should not be used as stop function! This might damage the actuator. Current
cut-offs should only be used in emergencies!
•
Current cut-off limits are not proportional with the load curves of the actuator. This means that
the current cut-offs cannot be used as load indicator.
•
There are tolerances on the spindle, nut, gear wheels etc. and these tolerances will have an
influence on the current consumption for the specific actuator.
19,5mA
19mA
13mA
11mA
5mA
4,5mA