Actuator with endstop signals and absolute positioning - PWM
Connection diagram:
Fig. 8 : 33xxxxxxxx0Fxxxx=xxxx1xxxxxxxx
BROWN
BLUE
PWM
YELLOW*
GREEN*
IN
OUT
RED
VIOLET
+
BLACK
-
The signal power must be turned on at all times when the actuator is running, and minimum one
second before it starts to run.
*YELLOW/GREEN: Endstop signals out are NOT potential free! (See I/O Specifications, page 15)
If you wish to use the endstop signals, you will have to keep power on the brown, blue, red and black wires,
otherwise the signal will be lost.