Fig. 4.5. Device installation. Tank made of non-conductive material.
4.2 Position for installation
The best location and orientation of level transmitters in the space depends on the
dimensions and structure of the tank, the number and location of product filling and
unloading points. Before ordering level transmitters, the number of transmitters in-
stalled on each tank, installation location and the orientation of transmitters in space
(sensor rotation about its axis and tilt) shall be agreed.
For the best choice of installation location, provide the following data on the in-
tended use:
1. The name of measured product;
2. Product density;
3. Tank shape (cylindrical bin, rectangular bin, open dump, a dome-shaped tank,
etc.);
4. The dimensions of tank and its components (for example, in a cylindrical tank,
the dimensions of cylindrical and conical parts.). Provide drawings or sketches with
dimensions;
5. Presence of internal structures. Specify the location of internal structures, if any,
indicating the dimensions;
6. Possible installation locations. Roof thickness and roof material.
7. Specify all existing filling and discharge points of the tank. Provide drawings or
sketches with dimensions;
19
RE_ULM3DX_18_02_20
Содержание ULM-3D Series
Страница 4: ...all dimensions of ULM 3D 5 54 13 4 Handling of cable gland 56 4 RE_ULM3DX_18_02_20 ...
Страница 24: ...Fig 4 13 Installation examples 24 RE_ULM3DX_18_02_20 ...
Страница 29: ...13 Switch matching load of RS 485 line RA B 120 Ohm 29 RE_ULM3DX_18_02_20 ...
Страница 53: ...13 2 Level transmitter connection to the mount flange and overall dimensions of ULM 3D 5 53 RE_ULM3DX_18_02_20 ...
Страница 55: ...Installation of ULM 3D 1 level transmitter on a nozzle 55 RE_ULM3DX_18_02_20 ...