13. APPENDICES
13.1 Technical specifications
Name
Description
General information
Housing material
Aluminum casting alloy, anodized,
powder coating
Sealing material between the housing
and the cover
Rubber compound
Aerial shield material
Polyethylene, fluoroplastic
Bluetooth module plug material
Fluoroplastic
Cable gland material
Nickel-plated brass
Weight, kg, max
ULM-3D-5
ULM-3D-1
11
3
Overall dimensions, mm, max
ULM-3D-5
ULM-3D-1
330х330х235
205х170х135
Type of installation on the process
flange
Output signals
Analog
4-20 mA
Active
Alarms
3 ma, 21 mA (installable)
Load
300 Ohm max
Error (in the temperature range -
40...+60°C)
0.25% of the measurement range max
Digital
RS-485
Modbus RTU
Resolution
0.1 mm
Wireless
Bluetooth
Version 4.0 or higher
Relay outputs
only ULM-3D-1
Number of channels
2
Maximum switching current
3 A
Maximum switching voltage, alternate
(direct)
250V (30V)
50
RE_ULM3DX_18_02_20
Содержание ULM-3D Series