13.4 Handling of cable gland
Cable gland design
Зажимная гайка
Clamp nut
Обжимная гильза
Clamping sleeve
Кольцо
Ring
Корпус
Housing
Профильное уплотнение
Cross-sectional sealing
IP rating:
IP 68 - 10 bar / IP 69K within the specified cable diameter ranges and only with an addi-
tional round O-ring
External thread:
M 20 x 1.5
Cable diameter, (mm):
7 - 12
Wrench size:
22
Material:
Nickel-plated brass
Procedure for connecting the cable to the level transmitter
1.
Screw the cable gland into the level transmitter housing (Fig. 3.1, 3.2)
2. Loosen the clamp nut.
3. Run a cable of the appropriate diameter through the cable gland.
4. Tighten the clamp nut.
Special conditions for operation and installation.
Cable entries are only applicable for perma-
nently laid cables. The person installing the cable gland shall ensure that the cable tension does
not exceed permissible values.