![Lika RD6 Series Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/lika/rd6-series/rd6-series_user-manual_1915979039.webp)
then restart the SW_RD6_MODBUS_X.EXE program. It is not possible to connect
to the unit through the
Serial configuration
page; the operator must enter the
Upgrade Firmware
page and restart the firmware installation process from
point 6. Always make sure that the correct serial port of the personal computer
connected to the DRIVECOD unit is selected in the
Serial configuration
page.
LEDS L5 AND L6 SOLIDLY LIT GREEN AND LED L7 SOLIDLY LIT RED
While downloading data to the flash memory for upgrading the firmware of the
unit, if data transmission is cut off (for instance, due to the disconnection of the
serial cable or because the process is terminated), after 5 seconds the LEDs L5
and L6 light up solidly green, while the LED L7 lights up solidly red. The
COMMUNICATION ERROR. UPGRADE INSTALLATION ABORTED
warning
message is invoked to appear in the box in the bottom of the
Upgrade
Firmware
page. The upgrading process is necessarily aborted and the unit
cannot work as the firmware has been deleted before starting the update. To
restore the work condition of the unit, the operator must shut down and then
switch on the DRIVECOD unit first, then close and restart the
SW_RD6_MODBUS_X.EXE program. As soon as the power is turned on again,
the LED L5 lights up solidly green, the LED L6 is off while the LED L7 starts
blinking red at 2 Hz as the user program is not installed in the flash memory. It
is not possible to connect to the unit through the
Serial configuration
page;
the operator must enter the
Upgrade Firmware
page and restart the firmware
installation process from point 6. Always make sure that the correct serial port
of the personal computer connected to the DRIVECOD unit is selected in the
Serial configuration
page.
MAN RD6 MB E 1.1
Quick reference
39 of 92