LED L6
GREEN
Description
ON
A problem occurred while upgrading the firmware,
see the “5.7.1 If an installation issue occurs” section
on page 38.
Blinking
The device is sending or receiving a message
(network activity)
OFF
No send - receive activity
LED L7
RED
Description
ON
Active alarms, internal error. See the
OFF
No alarms active
Blinking at 2 Hz
While downloading data to the flash memory for
upgrading the firmware of the unit (see the “5.7
“Upgrade Firmware” page” section on page 36), if an
error occurs which stops the upgrading process (for
instance: a voltage drop and/or the switching off of
the ROTADRIVE unit), as soon as the power is turned
on again the LED starts blinking red at 2 Hz as the
user program is not installed in the flash memory (it
has been deleted previously). For any information on
restoring the unit please refer to the “5.7 “Upgrade
Firmware” page” section on page 36 and the “5.7.1
If an installation issue occurs” section on page 38.
Blinking at 10 Hz
While downloading data to the flash memory for
upgrading the firmware of the unit (see the “5.7
“Upgrade Firmware” page” section on page 36), the
LED blinks red at 10 Hz.
LED L5 LED L6 LED L7
Description
GREEN
ON
GREEN
ON
RED
ON
While downloading data to the flash memory for
upgrading the firmware of the unit (see the “5.7
“Upgrade Firmware” page” section on page 36), if
data transmission is cut off (for instance, due to the
disconnection of the serial cable or because the
process is terminated), after 5 seconds the LEDs come
on solidly green/red. At following power-on, the LED
L5 lights up solidly green, the LED L6 is off, while the
LED L7 starts blinking red at 2 Hz as the user program
is not installed in the flash memory (it has been
deleted previously). For any information on restoring
the unit please refer to the “5.7 “Upgrade Firmware”
page” section on page 36 and the “5.7.1 If an
installation issue occurs” section on page 38.
MAN RD6 MB E 1.1
Electrical connections
19 of 92
RD6 Modbus®