4.4.2 Setting the Baud rate and Parity bit (Figure 7)
WARNING
The power supply must be turned off before performing this operation!
Set the binary value of transmission rate and parity bit according to the
following table, considering that: ON = 1; OFF = 0.
Switch
Baud rate
Parity bit
0000
9600 bit/s
No parity
1000 (default)
9600 bit/s
Even
0100
9600 bit/s
Odd
1100
19200 bit/s
No parity
0010
19200 bit/s
Even
1010
19200 bit/s
Odd
EXAMPLE
Set the baud rate to 9600 bits per second and parity bit to Even:
Switches
1
2
3
4
Position
ON
OFF
OFF
OFF
Value
1
0
0
0
The data transmission rate which is currently set in the unit can be read next to
the