A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
9.18.2. Databits Setting
Command and Response
ç
SET•/MANAGEMENT/CONTROL/SERIAL/
<port>
.DataBits=
<databits>
æ
pw•/MANAGEMENT/CONTROL/SERIAL/
<port>
.DataBits=
<databits>
Parameters
The
<databits>
of the selected port can be set to the following values: 7, 8.
Example
ç
SET /MANAGEMENT/CONTROL/SERIAL/P1.DataBits=8
æ
pw /MANAGEMENT/CONTROL/SERIAL/P1.DataBits=8
9.18.3. Stopbits Setting
Command and Response
ç
SET•/MANAGEMENT/CONTROL/SERIAL/
<port>
.StopBits=
<stopbits>
æ
pw•/MANAGEMENT/CONTROL/SERIAL/
<port>
.StopBits=
<stopbits>
Parameters
The
<stopbits>
of the selected port can be set to the following values: 1, 2.
Example
ç
SET /MANAGEMENT/CONTROL/SERIAL/P1.StopBits=2
æ
pw /MANAGEMENT/CONTROL/SERIAL/P1.StopBits=2
9.18.4. Parity Setting
Command and Response
ç
SET•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Parity=
<parity>
æ
pw•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Parity=
<parity>
Parameters
The
<stopbits>
of the selected port can be set to the following values: None, Odd, Even, Mark, Space.
Example
ç
SET /MANAGEMENT/CONTROL/SERIAL/P1.Parity=Even
æ
pw /MANAGEMENT/CONTROL/SERIAL/P1.Parity=Even
9.18.5. Enabling the Port
Command and Response
ç
SET•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Enabled=
<logical_value>
æ
pw•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Enabled=
<logical_value>
Parameters
The
<logical_value>
can be
true
or
false
.
Example
ç
SET /MANAGEMENT/CONTROL/SERIAL/P1.Enabled=true
æ
pw /MANAGEMENT/CONTROL/SERIAL/P1.Enabled=true
9.19. Serial Port Configuration - Endpoint Devices
DIFFERENCE:
Only the UBEX-PRO20-HDMI-F110 endpoint model is built with RS-232 port.
9.19.1. BAUD Rate Setting
Command and Response
ç
SET•/MEDIA/CONTROL/UART/
<port>
/PORT.Baudrate=
<number>
æ
pw•/MEDIA/CONTROL/UART/
<port>
/PORT.Baudrate=
<number>
Parameters
Identifier
Parameter description
Value
Explanation
<number>
Baud rate value
0
4800
1
7200
2
9600
3
14400
4
19200
5
38400
6
57600
7
115200
Example
ç
SET /MEDIA/CONTROL/UART/P101/PORT.Baudrate=7
æ
pw /MEDIA/CONTROL/UART/P101/PORT.Baudrate=7