![LightProcessor PARADIME Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/lightprocessor/paradime/paradime_installation-and-operating-manual_1914911008.webp)
SUPPLY INPUT WIRING - (STAR CONFIGURATION MODELS ONLY)
The dimmer is designed to operate on the following power supplies. See figs. 6 and 7.
6 x 10 Amp models:
230V AC or 115V AC Single or Three phase & Neutral
Maximum input current 60Amps one phase.
Maximum input current 20Amps per phase.
6 x 16 Amp models:
230V AC or 115V AC Three phase & Neutral
Maximum input current 32Amps per phase.
6 x 20 Amp models:
230V AC or 115V AC Three phase & Neutral
Maximum input current 40 Amps per phase.
3 x 25 Amp models:
230V AC or 115V AC Three phase & Neutral
Maximum input current 25Amps per phase.
Ensure a mains power input cable of sufficient cross-section is used.
The input cable should be passed through a suitable cable restraining gland fitted in the 32mm. hole in the rear panel
service plate (or in the side of a wall-mount Paradime). Draw in the input and output cables. Make connections as
shown below.
Secure the earth conductor to the earth block:
For single phase supplies:
Where the Paradime is to be used single phase, the single incoming live conductor must be routed to the other two
phase inputs using the supplied single-phase links (packed inside the dimmer). Fit the links provided to link terminal P1
to P2 and P2 to P3. Connect the live phase conductor to terminal P2. Connect the neutral conductor to terminal N1.
For three phase & neutral
ENSURE THERE ARE NO SINGLE PHASE LINKS INSTALLED. IF THE PARADIME IS NEW, REMOVE THE BAG
CONTAINING THE SINGLE PHASE LINKS FROM WITHIN THE ENCLOSURE.
Connect the three Live phase conductors to terminals P1, P2 and P3.
Connect the neutral conductor to terminal N1.
Tighten the gland around the cable.
CONNECTING THE SUPPLY
LightProcessor Paradime, all variants, version 21, September 2003
Page lV
Fig. 7
Single Phase Connection
Three Phase Star Connection
Fig. 6