![LightProcessor PARADIME Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/lightprocessor/paradime/paradime_installation-and-operating-manual_1914911024.webp)
There are various messages that may be displayed. General status or information messages include:
DMX Received OK
DMX is selected and the unit is now receiving valid DMX data.
DMX Absent
DMX is selected but the unit is no longer receiving valid DMX.
Invalid Start
DMX is selected but incompatible data is being received.
Output Scene 'n'
Scene 'n' has been selected from the remote input.
Output Prog 'n'
Chase programme 'n' has been selected from the remote input.
No Preset Chosen
Remote has been selected as an input source but currently nothing is active.
Messages relating to critical faults and error conditions that may affect the operation of the unit include:
Over Temperature
The dimmer has been operated outside the recommended parameters and has reached
an unacceptable temperature. This may be due to changes in the ventilation arrangements,
a dirty fan or similar and will require the unit to be inspected and reset by the installer or
similar competent engineer.
Over temperature errors occur for a reason. Deal with the problem before re-setting the unit.
Service Required
This indicates that the last time the unit was used a critical fault occurred. The fault must be
dealt with and then the unit must be re-set by the installer or similar competent engineer
before it can be used again.
Zero Cross Fail
Zero cross module failure. Refer to installer. Module replacement may be necessary.
IIC Error
Temperature sensor failure. Refer to installer. Sensor replacement may be necessary.
Error messages must be cleared to allow the Paradime to continue operating. See the comments relating to menu 86
on page 10 of this manual and those relating to the Installer Hardware Lock on page VI of the installer instructions.
LightProcessor Paradime, all variants, version 21, September 2003
Page 14
SYSTEM MESSAGES