Input Voltage

Max Pull Force

Max Door Area

Max Door Weight (Balanced)

Max Door Height

Drive Mechanism

Opening / Closing Speed

LED

Limit Setting

Transformer

Radio Frequency

Coding Format

Status Display Transmitter

Code Storage Capacity

Caution Light Terminal

Working Temperature

Safety Protection

Protection Level

LPO0600

600 N

10 m

2

80kg

2400 - 3500mm

Chain/Belt

160mm/second

Electronic

433.92MHz

2X

Included

-40°C to +50°C

IP20

220 - 240V / 110 - 127V, 50-60Hz

LPO1000

1000 N

15 m

2

100kg

2400 - 3500mm

Chain/Belt

160mm/second

24V / 15pcs LED bulbs

Electronic

Overload Protection Technology

433.92MHz

Rolling Code (7.38 x 10

19

 Combinations)

2X

50 Different Codes

Included

-40°C to +50°C

Soft Start & Soft Stop, Photo Cell Option, Caution Light Option

IP20

LPO1200

1200 N

18 m

2

130kg

2400 - 3500mm

Chain/Belt

160mm/second

Electronic

433.92MHz

2X

Included

-40°C to +50°C

IP20

LPO0600

Rated Door Area:

10m

2

Rated Door Area:

15m

2

Rated Door Area:

18m

2

Standard Door Height

2400mm

Max Door Height

3500mm

LPO1000

LPO1200

TECHNICAL SPECIFICATIONS

25

Содержание LPO0600

Страница 1: ...st be carried out by a qualified or licensed person Attempting to install or repair the door operator without suitable technical qualification may result in severe personal injury death and or propert...

Страница 2: ...et Installation Steel Track Installation Sectional Steel Track Assembly Battery Backup Assembly optional Display Menu Instructions Programming Instructions Terminal Introduction and Application Manual...

Страница 3: ...e door comes into contact with a moving object 10 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and kn...

Страница 4: ...nance 8 Automatic safety reverse Automatic stop automatic reverse are controlled by the internal circuit boards 9 Soft start Soft stop Ramping speed up and down at the start and end of each cycle redu...

Страница 5: ...4 different doors with one transmitter 19 Applications With as little as 30mm required between the ceiling and the highest point of the door travel the operator can be flush mounted for low headroom...

Страница 6: ...lose to the operator installation point 5 There should be a minimum gap of 30mm between the bottom of the chain drive rail and the top of the garage door at its closest point refer to Fig 1 Important...

Страница 7: ...the straight arm to the bent arm with the bolt Position and bolt the arms to the top edge of the door using the bolt supplied STEP 5 Lift the garage door until the shuttle locks into the drive chain b...

Страница 8: ...sleeve 3 Parts Track As Fig 7 slide the C rail into the sleeve slide the D rail into the sleeve slide the E rail into the sleeve 2 Cut the plastic thread pull the screw rod along with inner chain to t...

Страница 9: ...Battery STEP 1 Fig 11 Assemble the battery the bracket as shown using the screws supplied STEP 2 Fig 12 Connect the battery to the operator STEP 1 Fig 13 Assemble the battery to the side of the operat...

Страница 10: ...m the function you need to set The system will then enter the interface to set the function d In the function settings the interface will display 0 A with a flashing dot e Press UP Down button to choo...

Страница 11: ...button The door will open 4 Short press DOWN button The door will close When the door is opening or closing it will stop if you press any key 5 Long press SET button Enter function setting interface 6...

Страница 12: ...til the door reaches the desired close position you will see u without dot on the display NOTE For fine adjustments toggle UP DOWN buttons f Now press the SET button to confirm the close position then...

Страница 13: ...3 Travel Speed Setting CAUTION If you changed the speed again it will cancel the previous travel limit The speed adjustment function will be available only after you reset the travel limit a Press an...

Страница 14: ...Down button once to set the auto close time 0 9 d Press UP button to increase the time or DOWN button to decrease the time The close time is 15second N N 0 9 The maximum time is 135s To disable Auto...

Страница 15: ...ning process but can t automatically close when it is stopped in its closing process 6 LED OFF Delay Time Setting a Press and hold SET button until 1 appears on the display next press the UP button un...

Страница 16: ...button once to set the reversal height while closing 0 9 d Press UP button to increase or DOWN button to decrease Figure 0 The door will return to the open limit position Figure 1 9 The door will reb...

Страница 17: ...ose the partial open function Figure 1 9 Set the partial open position of the whole travel One tenth to Nine tenths of the whole travel etc d Press SET button to confirm the settings and it will retur...

Страница 18: ...s at home d Press SET button to confirm the settings and it will return to standby status automatically and display ll NOTES 1 The buttons recognition is set on 1 as default 2 After coding the hand se...

Страница 19: ...return to standby status automatically and display ll NOTE The reversal height is set on 1 as default C Wicket Pass Door Switch Type Setting a Press and hold SET Button until 1 appears on the display...

Страница 20: ...e display to enter this function setting then release the button b Press the SET button again The unit is now in the photo cell ON OFF adjustment mode You will see a figure 0 with a flashing dot on th...

Страница 21: ...on the display Figure 2 The maintenance alarm count cycle is set on 2000 times Figure 3 The maintenance alarm count cycle is set on 3000 times Figure 4 The maintenance alarm count cycle is set on 4000...

Страница 22: ...d SET Button until 1 appears on the display next press the UP button until appears on the display to enter this function setting then release the button b Press the SET button again The unit is now in...

Страница 23: ...this function and provide 24v 35v flash light voltage Connect the flash light with DC 24v 28v current 100mA When use AC 220V power flash lights please match an adapter and wiring as required 3 Wicket...

Страница 24: ...ces are working effectively photo beams etc 2 Light bulb replacing Notice Make sure the power supply has been cut off before replacing the light bulb And ensure the voltage of the new light bulb is in...

Страница 25: ...0 C to 50 C IP20 220 240V 110 127V 50 60Hz LPO1000 1000 N 15 m2 100kg 2400 3500mm Chain Belt 160mm second 24V 15pcs LED bulbs Electronic Overload Protection Technology 433 92MHz Rolling Code 7 38 x 10...

Страница 26: ...eel Control Panel Cover 1 Mounting Bracket Control Panel Cover 2 Chain Wheel Main Cover Wheel Bracket LED Light Track Ending Bracket PCB 1 Wall Bracket PCB 2 Door Bracket DC Gear Motor Bent Arm Motor...

Страница 27: ...r motor and board is plugged inversely Photo cell function has been effective without connecting any photo cell device Automatic closing function is turned on The power board is broken Insufficient vo...

Страница 28: ...New remote control is not compatible with operator Motor shaft sleeve worn External devices is not compatible with the operator Stored remote code is full The Garage door system needs maintenance Doo...

Отзывы: