background image

EN

Sectional door operator STA 1 / Rev. D 0.3 – 1 

Operating Instructions 

STA 1 sectional door operator

Содержание STA 1

Страница 1: ...EN Sectional door operator STA 1 Rev D 0 3 1 Operating Instructions STA 1 sectional door operator...

Страница 2: ...ght No part of these instructions may be reproduced without our prior approval Subject to alterations in the interest of technical progress All dimensions given in mm The diagrams in this manual are n...

Страница 3: ...ed professionals fulfil the following requirements knowledge of the general and specific safety and accident prevention regulations knowledge of the relevant regulations trained in the use and care of...

Страница 4: ...anism HD STA STAW 1 KE HD external control unit with chain HD STA STAW 1 KU HD external control unit with emergency hand crank HD STAC STAWC 1 E integrated control unit with release mechanism STAC STA...

Страница 5: ...tion does not exceed 1 000 m a suitable protection type has been selected Before installation ensure that the drive is not blocked the drive has been newly prepared after a lengthy storage period all...

Страница 6: ...th two hose clamps or adjusting rings Fix the operator to the torque support bracket with 4 screws Installation 5 3 Installation of the emergency hand chain only for operators with emergency hand chai...

Страница 7: ...oints must be observed The types of cable and their diameters must be selected according to current regulations The nominal currents and the type of connection must correspond to those on the motor ty...

Страница 8: ...S3 Safety limit switch OPEN S4 Safety limit switch CLOSED S5 Limit switch CLOSED S6 Additional limit switch CLOSED standard only for operators without integrated control unit S7 Safety limit switch f...

Страница 9: ...Connect all the cables required Identification of wires AUF OPEN blue ZU CLOSE blue N red 6 3 Manual settings A B C D E F K J I H L G 6 3 1 A OPEN additional limit switch S1 potential free change over...

Страница 10: ...a way that it switches immediately when the CLOSED limit switch E is passed over Adjust the CLOSED safety limit switch D M N Set the OPEN end position Drive the door to the OPEN end position Set the c...

Страница 11: ...on commands change the direction of rotation The direction of movement must then be checked again REFERENCE Please refer to the control unit operating manual for instructions on changing the direction...

Страница 12: ...er completing emergency manual operation 7 Emergency operation WARNING Improper use may result in serious injury To avoid injury the following points must be observed Emergency operation must only be...

Страница 13: ...N Improper maintenance of the drive can result in property damage To avoid damage to the drive and door the following points must be observed Maintenance must only be carried out by authorized persons...

Страница 14: ...ntrol voltage V 24 24 24 24 24 24 Nominal motor current A 3 5 2 0 3 5 2 0 3 1 1 8 4 1 2 4 4 1 2 4 3 5 2 0 Maximum no of operating cycles per hour 20 20 20 20 20 20 Fuse protection on site A 10 0 10 0...

Страница 15: ...V 24 24 24 24 24 Nominal motor current A 3 1 1 8 3 0 1 7 3 0 1 7 3 0 1 7 6 2 Maximum no of operating cycles per hour 30 30 30 30 8 Fuse protection on site A 10 0 10 0 10 0 10 0 10 0 Protection type IP...

Страница 16: ...STA STAW 1 KE 55 105 140 245 55 108 6 35 25 4 120 A 104 102 409 145 90 3 5 166 9 2 A 4x M8x16 deep on both sides STA STAW 1 E 55 108 55 140 245 1 2 0 A 6 35 25 4 50 104 369 102 145 105 3 5 166 9 1 A...

Страница 17: ...0 3 17 EN STA STAW 1 KU 55 140 55 108 120 A 6 35 3 5 25 4 245 104 105 145 399 80 102 166 9 3 A 4x M8x16 deep on both sides STA STAW 1 E HD 55 108 55 140 245 120 6 35 25 4 145 3 5 104 A 105 336 183 13...

Страница 18: ...STAW 1 KE HD 55 140 245 55 108 6 35 25 4 120 145 105 180 150 A 104 191 105 438 3 5 9 5 A 4x M8x16 deep on both sides STA STAW 1 KU HD 55 55 108 120 6 35 3 5 25 4 105 140 245 145 A 104 136 180 396 63 9...

Страница 19: ...3 19 EN STAC STAWC 1 KE 55 108 55 105 140 245 120 A 6 35 3 5 25 4 104 145 90 406 102 166 9 8 A 4x M8x16 deep on both sides STAC STAWC 1 E 55 105 245 140 55 108 145 50 A 3 5 25 4 6 35 120 104 369 102...

Страница 20: ...20 Sectional door operator STA 1 Rev D 0 3 STAC STAWC 1 KU 55 140 245 55 108 120 A 6 35 25 4 104 105 145 3 5 399 80 102 166 9 9 A 4x M8x16 deep on both sides Technical data...

Страница 21: ...Sectional door operator STA 1 Rev D 0 3 21 EN...

Страница 22: ...N 60335 1 Household and similar electrical appliances Safety Part 1 General requirements EN 60335 2 103 Household and similar electrical appliances Safety Part 2 103 Particular requirements for drives...

Страница 23: ...EN Sectional door operator STA 1 Rev D 0 3 23 In case of changes to the product that are not confirmed by us this declaration is void Legden dated 01 07 2018 Dirk Wesseling General Manager...

Страница 24: ...1700007835 97609...

Отзывы: