8 – Sectional door operator STA 1 / Rev. D 0.3
Sectional door operator STA 1 / Rev. D 0.3 – 9
EN
3 x 400 V star connection (standard)
The motor is factory-wired for connection to a 3 x 400 V
mains supply in star connection.
6.2 / 7
☞
Connect all the cables required.
Identification of wires
U1 Red
V1 Blue
W1 White
V2 Black
W2 Brown
U2 Green
3 x 230 V delta connection
To connect the operator to a 3 x 230 V mains supply, please
consult the manufacturer.
1 x 230V connection
The motor is factory-wired for connection to a 230V/1-phase
mains supply.
AUF
ZU
PE
N
6.2 / 8
☞
Connect all the cables required.
Identification of wires
AUF (OPEN)
blue
ZU (CLOSE)
blue
N red
6.3 Manual settings
A
B
C
D
E
F
K
J
I
H
L
G
6.3 / 1
A
OPEN additional limit switch - S1
(potential-free change-over contact)
B
Limit switch, OPEN - S2
C
Safety limit switch, OPEN - S3
D
Safety limit switch, CLOSED - S4
E
Limit switch, CLOSED - S5
F
Additional limit switch, CLOSED - S6
(potential-free change-over contact)
G
Control cam for additional limit switch, OPEN (green)
H
Control cam for limit switch, OPEN (green)
I
Control cam for safety limit switch, OPEN (red)
J
Control cam for safety limit switch, CLOSED (red)
K
Control cam for limit switch, CLOSED (white)
L
Control cam for additional limit switch, CLOSED
(white)