10 – Sectional door operator STA 1 / Rev. D 0.3
Sectional door operator STA 1 / Rev. D 0.3 – 11
Initial Operation
6.3 / 2
M
Fine adjustment screw
N
Locking screw
Each control cam has a locking screw (N) and a fine adjust-
ment screw (M).
The locking screw (N) is used to lock the corresponding
control cam in the desired position. Finer adjustment can be
made with the fine adjustment screw (M).
Set the CLOSED end position
☞
Drive the door to the CLOSED end position.
☞
Set the control cam (K) so that the CLOSED limit switch (E)
is actuated.
☞
Tighten the locking screw (N).
The CLOSED safety limit switch (D) must be set in such a way
that it switches immediately when the CLOSED limit switch (E)
is passed over.
☞
Adjust the CLOSED safety limit switch (D).
M
N
Set the OPEN end position
☞
Drive the door to the OPEN end position.
☞
Set the control cam (H) so that the OPEN limit switch (B) is
actuated.
☞
Tighten the locking screw (N).
The OPEN safety limit switch (C) must be set in such a way
that it switches immediately when the OPEN limit switch (B)
is passed over.
☞
Adjust the OPEN safety limit switch (C).
6.4 Digital settings –
Limit switch and safety circuit for drive
Electronic interface
6.4 / 1
A
B
A:
AVE plug (absolute value encoder plug)
B:
AVE plug terminal (absolute value encoder plug
terminal)
REFERENCE
Please refer to the control unit operating manual for
instructions on setting the end positions.