6 – Sectional door operator STA 1 / Rev. D 0.3
Sectional door operator STA 1 / Rev. D 0.3 – 7
EN
6.1 Preparation
DANGER!
Danger of fatal electric shock!
☞
Before commencing cabling works, you MUST disconnect
the drive system from the mains supply. Ensure that the
electricity supply remains disconnected throughout the
cabling works.
ATTENTION!
Damage due to improper installation of the drive!
To avoid damage to the drive, the following points must be
observed:
− The types of cable and their diameters must be selected
according to current regulations.
− The nominal currents and the type of connection must
correspond to those on the motor type plate.
− The drive details must agree with the connected loads.
REFERENCE
When operated with electronic control units, the
corresponding start-up instructions and circuit diagrams
must be complied with.
6. Initial Operation
6.2 Connection
Open the operator
6.2 / 1
☞
Remove the cover from the operator.
Insert the cables
6.2 / 2
☞
Feed the cables through the screw fitting into the operator.