Sectional door operator STA 1 / Rev. D 0.3 – 13
EN
12 – Sectional door operator STA 1 / Rev. D 0.3
Sectional door operator STA 1 / Rev. D 0.3 – 13
Operation with release mechanism
WARNING!
Risk of serious injury due to uncontrolled
movement of the door!
To avoid injury, drive units with a release mechanism
require that a fall protection is mounted on the door.
Without a fall protection, the door does not comply with
directive ASR A1.7.
7 / 3
☞
Pull on the red loop.
The gate can be moved manually.
☞
Pull on the green loop.
The door can be moved with the operator.
DANGER!
Danger of fatal electric shock!
☞
Before commencing cabling works, you MUST disconnect
the drive system from the mains supply. Ensure that the
electricity supply remains disconnected throughout the
cabling works.
ATTENTION!
Improper maintenance of the drive can result in
property damage!
To avoid damage to the drive and door, the following points
must be observed:
− Maintenance must only be carried out by authorized
persons.
− Directive ASR A1.7 must be complied with.
− Worn or faulty parts must be replaced.
− Only approved parts must be installed.
− All maintenance work must be documented.
The drive unit has lifetime lubrication and is maintenance-
free.
The hollow shaft must be kept rust-free.
☞
Check that all mountings have been securely tightened.
☞
Check the spring tension on the door.
The springs must be adjusted so that they are weight counter-
balanced.
☞
Check the brake (if available).
☞
Check the limit switches and safety switches.
☞
Check for noises and oil leaks.
☞
Check the mounting of the drive for corrosion.
☞
Check the housing for damage.
Faulty parts that have been replaced must be disposed of
properly in accordance with the regulations.
8. Maintenance