Symptom: Battery Over-Heating
Symptom
Probable Cause
Corrective Action
Battery over-heating during
exercise program.
Battery Wires incorrectly
connected
Inspect connections: red wire to positive (+)
lead; black wire to negative (-) lead.
Worn Battery Wires
Inspect Wires. Replace Wires or harness.
Battery leads grounding upon
frame
Inspect leads. Replace battery.
Malfunctioning Display Console
Test with substitute Display Console. Replace
malfunctioning Display Console.
Malfunctioning Alternator
Control Board
Test with substitute Alternator Control Board.
Replace defective board.
For Assistance Contact
Life Fitness Customer Support Services
Teleph.: 847.451.0036 or 800.351.3737
Telefacs.: 847.288.3702 or 800.216.8893
Содержание Lifecycle 9500RHR Series
Страница 6: ...Lifecycle 9500RHR Series Exercise Bikes SECTION I TROUBLESHOOTING GUIDES ...
Страница 27: ...Lifecycle 9500RHR Series Exercise Bikes NOTES 2 ...
Страница 28: ...Lifecycle 9500RHR Exercise Bike SECTION II DIAGNOSTIC MODES ...
Страница 41: ...Lifecycle 9500RHR Exercise Bike NOTES 14 ...
Страница 42: ...SECTION III How To SERVICE AND REPAIR GUIDES ...
Страница 67: ...Life Cycle 9500RHR Series Exercise Bikes SECTION IV WIRING BLOCK DIAGRAMS AND PARTS IDENTIFICATION ...
Страница 70: ...Life Cycle 9500RHR Series Exercise Bikes SECTION IV WIRING BLOCK DIAGRAMS AND PARTS IDENTIFICATION ...
Страница 100: ...Lifecycle 9500RHR Series Exercise Bikes 1 Lifecycle 9500RHR Series Exercise Bikes SECTION V MISCELLANEOUS INFORMATION ...
Страница 101: ...Lifecycle 9500RHR Series Exercise Bikes 2 MODEL IDENTIFICATION and SERIAL NUMBER LOCATION Serial Number ...
Страница 105: ...Lifecycle 9500RHR Series Exercise Bikes 6 MISCELLANEOUS NOTES ...