2) Sensor resistance characteristics table
u
Resistance value allowance of sensor is ±5%.
u
When measuring the resistance value of the sensor, allow the temperature of that sensor to stabilize for at least 3 minutes
before measuring. This delay is necessary because of the sense speed relationship.
u
Use a digital tester to measure the resistance. An analog tester has to great a margin of error.
u
Resistance of the cold storage sensor 1 and 2 shall be measured with a digital tester after separating CON8 of the PWB
ASSEMBLY and the MAIN part.
u
Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.
EXPLANATION FOR MICOM CIRCUIT
- 43 -
Measuring Temperature (°C)
Freezing Sensor
Refrigerator sensor 1&2
Defrost sensor, Ambient sensor
-20 °C
22.3 k
Ω
77 k
Ω
-15 °C
16.9 k
Ω
60 k
Ω
-15 °C
13.0 k
Ω
47.3 k
Ω
-5 °C
10.1 k
Ω
38.4 k
Ω
0 °C
7.8 k
Ω
30 k
Ω
+5 °C
6.2 k
Ω
24.1 k
Ω
+10 °C
4.9 k
Ω
19.5 k
Ω
+15 °C
3.9 k
Ω
15.9 k
Ω
+20 °C
3.1 k
Ω
13 k
Ω
+25 °C
2.5 k
Ω
11 k
Ω
+30 °C
2.0 k
Ω
8.9 k
Ω
+40 °C
1.4 k
Ω
6.2 k
Ω
+50 °C
0.8 k
Ω
4.3 k
Ω
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...