2-7. Sound
TROUBLE DIAGNOSIS
- 75 -
Problems
Causes
Checks
Measures
Remarks
Hiss
sound
1. Loud sound of compressor
1.1 Check the level of the
1) Maintain horizontal level.
operation.
refrigerator.
2) Replace bushing and seat if they
1.2 Check the bushing seat
are sagged and aged.
conditions (sagging and aging).
3) Touch the piping at various place
along its route. Install a damper at
2. Pipes resonate sound which is
2.1 Check the level of pipes
the point where your touch reduces
connected to the compressor.
connected to the compressor
the noise.
and their interference.
4) Avoid pipe interference.
2.2 Check bushing inserting
5) Replace defective fan and fan
conditions in pipes.
motor.
2.3 Touch pipes with hands or screw
6) Adjust fan to be in the center of
-driver (check the change of
the fan guide.
sound).
7) Leave a clearance between
interfering parts and seal gaps in
3. Fan operation sound in the freezer
3.1 Check fan insertion depth and
the structures.
compartment.
blade damage.
8) Reassemble the parts which make
3.2 Check the interference with
sound.
structures.
9) Leave a clearance if evaporator
3.3 Check fan motor.
pipes and suction pipe touch
3.4 Check fan motor bushing
freezer shroud.
insertion and aging conditions.
4. Fan operation sound in the
4.1 Same as fan confirmation in the
compressor compartment.
refrigerator.
4.2
Check the drip tray support installation.
4.3 Check the screw fastening
conditions at condenser and
drip tray.
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...