TROUBLE DIAGNOSIS
- 65 -
CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
8. Faulty lamp
(freezer and
refrigerator
compartment).
9. Faulty internal
voltage (short).
1) Lamp problem.
Filament blows out.
Glass is broken.
2) Bad lamp assembly.
Not inserted.
Loosened by vibration.
3) Bad lamp socket.
Disconnection.
Bad soldering.
Bad rivet contact.
Short.
Water penetration. Low water
level in tray.
Bad elasticity of contact.
Bad contact(corrosion).
4) Door switch.
Defective.
Refrigerator and freezer switches are reversed.
Travlel distance.
Bad connection.
Bad terminal contact.
Adiabatics liquid leak.
1) Lead wire is damaged.
Wire damage when assembling PTC Cover.
Outlet burr in the bottom plate.
Pressed by cord heater. lead wire, evaporator pipe.
2) Exposed terminal.
Compressor Compartment terminal. - Touching other
components.
Freezer compartment terminal. - Touching evaporator pipe.
3) Faulty parts.
Transformer.
Coil contacts cover.
Welded terminal parts contact cover.
Compressor.
Bad coil insulation.
Plate heater.
Melting fuse.
Sealing is broken.
Moisture penetration.
Cord heater.
Pipe damaged.
Moisture penetration.
Bad sealing.
Sheath heater.
■
Connect conduction and
non-conduction parts and
check with tester.
Conduction: NG.
Resistance
∞
: OK.
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...