2. Compensation circuit for temperature at freezer
(1) GR-L277SV(S)VA, SSWA (LSC27950SW, LSC27950SB, LSC27950ST, LSC27960ST)
u
This circuit allows adjustment of the set temperature for compensation by changing jumpers at locations JCR1~JCR4.
EXPLANATION FOR MICOM CIRCUIT
- 40 -
Compensation Compensation
for too warm
for too cold
Temperature compensation value
Remarks
JCR3
JCR4
JCR1
JCR2
at refrigerator
0 °C (In shipment from factory)
CUT
-1 °C [-1.8 °F]
CUT
-1 °C [-1.8 °F]
CUT
+1 °C [+1.8 °F]
CUT
+1 °C [+1.8 °F]
CUT
CUT
-2 °C [-3.6 °F]
CUT
CUT
+2 °C [+3.6 °F]
CUT
CUT
0 °C [0 °F]
CUT
CUT
0 °C [0 °F]
CUT
CUT
0 °C [0 °F]
CUT
CUT
0 °C [0 °F]
CUT
CUT
CUT
-1 °C [-1.8 °F]
CUT
CUT
CUT
+1 °C [+1.8 °F]
CUT
CUT
CUT
CUT
0 °C [0 °F]
Temperature compensation in CUT
JCR1
+1 °C [+1.8 °F]
+2 °C [+3.6 °F]
JCR2
+1 °C [+1.8 °F]
JCR3
-1 °C [-1.8 °F]
-2 °C [-3.6 °F]
JCR4
-1 °C [-1.8 °F]