2-4. Cooling
TROUBLE DIAGNOSIS
- 69 -
Problems
Causes
Checks
Measures
Remarks
High
Refrigerant leak.
Check sequence
Weld the leaking part, recharge the
Drier must be replaced.
temperature
1. Check the welded parts of the
refrigerant.
in the freezer
drier inlet and outlet and drier
compartment.
auxiliary in the compressor
compartment (high pressure side).
2. Check the end of compressor
sealing pipe (low pressure side).
3. Check silver soldered parts.
4. Check bending area of wire
condenser pipe in compressor
compartment (cracks can
happen during bending).
5. Check other parts (compressor
compartment and evaporators in
freezer compartment).
Shortage of refrigerant.
Check frost formation on the surface
- Find out the leaking area, repair,
Drier must be replaced.
of evaporator in the freezer
evacuate, and recharge the
compartment.
refrigerant.
- If the frost forms evenly on the
- No leaking, remove the remaining
surface, it is OK.
refrigerant, and recharge new
- If it does not, it is not good.
refrigerant.
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...