2-12. Ringing of manual operation, manual frost defrost buzzer
1. The buzzer sounds briefly when the test button on the main PCB is pressed.
2. If you select manual operation, the buzzer sounds three times for
2
/
10
second each, then it sounds three times for
2
/
10
second each every thirty seconds until the door is closed.
3. If you select manual defrost, the buzzer sounds three times for
2
/
10
second each, then it sounds three times for
2
/
10
second
each every thirty seconds until the door is closed.
2-13. Defrost function
1. Defrost is cycled whenever the compressor’s runtime reaches 7 ~ 7
hours.
2. In providing initial power (or returning power failure), defrost starts whenever total operation time of compressor becomes
4 ~ 4
hour.
3. Defrost is completed if temperature of a frost removal sensor becomes more than 5°C after starting frost removal. Poor
frost removal is not displaced if it does not arrive at 5°C even if two hours have passed after starting frost removal.
4. No defrost cycle is run if the defrost sensor fails.
2-14. Refrigerator room lamp automatic off
• Refrigerator room lamp turn on and off by refrigerator door switch.
• If refrigerator room lamp continuously turns on more than 7 minutes, the refrigerator room lamp turns off automatically.
MICOM FUNCTION
- 19 -
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...