2-3. Temperature
TROUBLE DIAGNOSIS
- 68 -
Problems
Causes
Checks
Measures
Remarks
High
Poor cool air circulation due to faulty
- Lock
––
Check resistance with a
- Replace fan motor.
temperature
fan motor.
tester.
in the freezer
0
Ω
: short.
compartment.
∞Ω
: cut.
- Reconnect and reinsert.
- Rotate rotor manually and check
rotation.
- Wire is cut.
- Check for bad terminal
- Maintain clearance and remove ice
connection.
(Repair and/or replace shroud if fan
- Fan constraint.
–
Fan shroud
is constrained by shroud
contact: Confirm
deformation).
visually.
–
Fan icing:
Confirm visually.
Faulty fan motor due to faulty door
- Iced button (faulty) operation:
- Confirm icing causes and repair.
switch operation.
Press button to check
- Replace door switch.
- Faulty button pressure and contact:
Press button to check operation.
- Door cannot press door switch
- Door sag: fix door.
button: Check visually.
- Door liner bent: replace door or
attach sheets.
Poor heat exchange
- Check the clearance between the
- Keep clearance between
- The fan may be
in compressor area.
refrigerator and wall minimum of
refrigerator and walls minimum of
broken of damaged
4
50 mm).
4
50 mm).
if cleaned while the
- Check dust on the grill in
- Remove dust and contaminants
refrigerator is
compressor compartment.
from grill for easy heat radiation.
running.
- Check dust on the condenser coils.
- Remove the dust with vacuum
cleaner from the coils condenser
while the refrigerator is off.
Содержание LSC 27950SB
Страница 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Страница 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Страница 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Страница 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Страница 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...
Страница 108: ...P No 3828JD8970B JAN 2006 Printed in Korea ...