Ceiling Concealed Duct
8
_ Inverter
50Hz/R410A
Part 3 Design and installation
n
Wide Wired Remote Controller
Function Code
Thermistor setting
Set Thermistor value by pressing
button. (01: Remote Controller,
02: Indoor, 03: 2TH)
3
Press button to save.
4
5
If moving to room temperature perception
sensor selection menu by pressing
button, it indicates as picture below.
2
If pressing button long for 3
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
1
Pressing button will exit settings mode.
❈
After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈
When exiting without pressing set button,
the manipulated value is not reflected.
<Thermistor Table>
j
The function of 2TH has different operation characteristics according to the product.
Temperature sensor selection
Function
01
Remote controller
Operation in remote controller temperature sensor
02
Indoor unit
Operation in indoor unit temperature sensor
03
2TH
Cooling
Operation of higher temperature by comparing indoor unit's and wired remote controllerʼs
temperature.
(There are products that operate at a lower temperature.)
Heating
Operation of lower temperature by comparing indoor unit's and wired remote controller's tem-
perature.
1. Installation
Содержание B30AWYN7G5A
Страница 1: ...Ceiling Concealed Duct Inverter 50Hz R410A 5CSB0 02B Replace 5CSB0 02A P No MFL49500009 ...
Страница 4: ...Part 1 General information 1 Models List 2 Nomenclature 3 Features Benefits Ceiling Concealed Duct ...
Страница 52: ...Part 3 Design and installation 1 Installation Ceiling Concealed Duct ...
Страница 75: ...Part 4 Accessories 1 Function of Remote Control 2 Central Control Devices Ceiling Concealed Duct ...