44 Room Air Conditioner
Operation
• Function used to perform the Self Cleaning to prevent the Unit from Fungus and Bad Odors.
• Used after the Shut Down of Cooling Operation to Clean the Evaporator and keep it as fresh for the Next operation.
• During Self Cleaning the Outdoor Unit is Switched off.
• The function is easy to be operated as It is accessed through the Remote Controller.
Auto Cleaning
Auto Changeover
Low Ambient
Comp.
ON
ON
OFF
OFF
Setting Step
Low
Indoor Fan
ON
2) Cooling/only Model
Cool Start
Cooling CYCLE
OFF
20 Sec
30 Min
Fan
ON
1) Heat/pump Model
Cool Start
Cooling CYCLE
OFF
Comp.
ON
ON
ON
OFF
OFF
Indoor Fan
OFF
Setting Step
Low
Low
Low
13 Min
20 Sec
Heating
Fan
60 Sec 120 Sec
Fan
• The air conditioner changes the operation
mode automatically to keep indoor tempera-
ture.
• When room temperature vary over ±2°C with
respect to setting temperature, air condition-
er keeps the room temperature in ±2°C with
respect to setting temperature by auto
change mode.
• If outdoor temperature drops below certain temperature,liquid back is prevented by reducing fan speed.
It can prevent frosting of evaporator and keep cooling operation
• No matter even if the outdoor temperature reaches -10°C.
• You can Cool your room at your desired temperature all your around.
Freq.
- 0
°
C
°
…
Outdoor temp.
Outdoor pipe temp.
0
°
C outdoor fan On/Off
control
°
Comp Freq.
Outdoor fan
On
On
Off
Off
Outdoor temp.:-10
°
C
-5
0
5
10
15
20
25
0
50
100
150
200
Time(Min.)
Temp.(
°
C)
Outdoor fan On/Off control
Cond . temp.
COOLING
Auto
Change
Mode.
Outdoor temp.
Indoor temp.
Outdoor
temp.
30
°
C
20
°
C
10
°
C
+2
°
C
+1
°
C
+0.5
°
C
Set Temp.
-0.5
°
C
-1
°
C
-2
°
C
HEATING
Содержание AS-W096QGG1
Страница 48: ...48 Room Air Conditioner Schematic Diagram Schematic Diagram Electric Control Device Indoor ...
Страница 49: ...Service Manual 49 Schematic Diagram Outdoor AS W096_Series AS W126_Series ...
Страница 50: ...50 Room Air Conditioner Schematic Diagram Outdoor AS W186_Series AS W246_Series ...
Страница 55: ...Service Manual 55 Schematic Diagram OUTDOOR MAIN P W B ASSEMBLY AS W096QGG1 AS W126RGH1 BOTTOM VIEW TOP VIEW ...
Страница 84: ...P No 3828A20195S February 2007 Printed in Korea ...