8. Installation
37
MULTI/SINGLE
Indoor unit
Wall Mounted Unit (2)
Drill a Hole in the wall
Drain Piping
8.3 Wiring the cable to the indoor units
8.3.1 General instructions
• All field supplied parts and materials, electric works must conform to local codes. Use copper wire only.
• Follow the
"WIRING DIAGRAM”
attached to the unit body to wire the outdoor unit, indoor units and the remote
controller.
• All wiring must be performed by an authorized electrician.
• A circuit breaker capable of shutting down the power supply to the entire system must be installed.
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1.Drill the piping hole with a ø 70mm hole core drill.
Drill the piping hole at either the right or the left with
the holes slightly slanted to the outdoor side.
1.The drain hose should point downward for easy
drain flow
2.Do not make drain piping like the following.
* The feature can be changed according to type of model.
Wall
5~7mm
Indoor
Outdoor
Downward slope
Do not raise
Water
leakage
Accumulated
drain water
Air
Waving
Water
leakage
Tip of drain hose
dipped in water
Water
leakage
Ditch
Less than
50mm gap
Содержание AM07BP NSJ
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 02A Replaces 0CTI5 01C P No MFL67502513 ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 33: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 5 Wiring Diagrams Deluxe Model AMNW07GSJL0 DM07RP NSJ ...
Страница 140: ...MULTI SINGLE Indoor unit 3 Dimensions 14 Ceiling Mounted cassette 4 way ZTNW18GQLA0 CT18R NQ0 ...
Страница 141: ...3 Dimensions 15 MULTI SINGLE Indoor unit Ceiling Mounted cassette 4 way ZTNW24GPLA0 CT24R NP0 ...