2. Specifications
12
MULTI/SINGLE
Indoor unit
Wall Mounted Unit
Model Name
USNW09GJ2F0
[PM09SP NSJ]
USNW12GJ2F0
[PM12SP NSJ]
Power Supply
V, Ø, Hz
220-240, 1, 50
220-240, 1, 50
220, 1, 60
220, 1, 60
Capacity
Cooling
kW
2.5
3.5
Heating
kW
3.2
3.8
Power Input
Min./Nom./Max.
W
11 / 18 / 30
11 / 19 / 30
Running Current
Min./Nom./Max.
A
0.10 / 0.16 / 0.20
0.10 / 0.17 / 0.20
Casing Color
-
Munsell 7.5BG 10/2 (RAL 9016)
Dimensions
Body
W x H x D
mm
837 × 308 × 189
837 × 308 × 189
W x H x D
inch
32-15/16 x 12-1/8 x 7-7/16
32-15/16 x 12-1/8 x 7-7/16
Shipping
W x H x D
mm
909 x 383 x 256
909 x 383 x 256
W x H x D
inch
35-25/32 x 15-3/32 x 10-3/32
35-25/32 x 15-3/32 x 10-3/32
Weight
Body
kg (lbs)
8.7 (19.2)
8.7 (19.2)
Shipping
kg (lbs)
12.0 (26.5)
12.0 (26.5)
Heat Exchanger
(Row x Column x Fins per inch) x
No.
-
(2 x 15 x 21) x 1
(2 x 15 x 21) x 1
Face Area
m
2
(ft
2
)
0.19 (2.05)
0.19 (2.05)
Fan
Type
-
Cross Flow Fan
Cross Flow Fan
Air Flow Rate
H / M / L
m
3
/min
9.2 / 7.4 / 5.6
9.6 / 8.1 / 5.6
H / M / L
ft
3
/min
325 / 261 / 198
339 / 286 / 198
Fan Motor
Type
-
BLDC
BLDC
Output
W x No.
30 x 1
30 x 1
Sound Pressure Level
H / M / L
dB(A)
36 / 33 / 27
40 / 35 / 27
Sound Power Level
Max.
dB(A)
57
57
Piping Connections
Liquid
mm(inch)
Ø 6.35 (1/4)
Ø 6.35 (1/4)
Gas
mm(inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Drain
O.D. / I.D.
mm
Ø 21.5 / 16.0
Ø 21.5 / 16.0
Safety Devices
-
Fuse
-
Thermal Protector for Fan Motor
Connections Method
-
Flared
Flared
Power and Communication Cable (included Earth)
No. x mm
2
(AWG)
4C x 1.0 (18)
4C x 1.0 (18)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national code. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values depend on the ambient conditions and values are normally higher
in actual operation.
4. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
Содержание AM07BP NSJ
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 02A Replaces 0CTI5 01C P No MFL67502513 ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 33: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 5 Wiring Diagrams Deluxe Model AMNW07GSJL0 DM07RP NSJ ...
Страница 140: ...MULTI SINGLE Indoor unit 3 Dimensions 14 Ceiling Mounted cassette 4 way ZTNW18GQLA0 CT18R NQ0 ...
Страница 141: ...3 Dimensions 15 MULTI SINGLE Indoor unit Ceiling Mounted cassette 4 way ZTNW24GPLA0 CT24R NP0 ...