MULTI/SINGLE
Indoor unit
8. Installation
36
Wall Mounted Unit (2)
8.2.3 Finishing the indoor unit installation
CAUTION
•
The indoor unit can be dropped from the wall, the indoor unit is not screwed correct position on the
install plate.
•
To avoid the gap between the indoor unit and wall , screw the indoor unit to the install plate correctly.
8.2.4 Checking the Drainage
To check the drainage.
1.Mount the tubing holder in the original
positon.
2.Ensure that the hooks are properly seated on
the installation plate by moving it left and
right.
3.Press the lower left and right sides of the unit
against the installation plate until the hooks
engage into their slots (clicking sound).
4.Finish the assembly by screwing the unit to
the installation plate by using two pieces of
type "C" screws. And assemble a chassis
cover. (SJ/SK chassis) Recovery the chassis
cover in Original place. (SV chassis)
* The feature can be changed according to type of model.
1.Pour a glass of water on the evaporator.
2.Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.
* The feature can be changed according to type of model.
Type 'C' screw
Drain pan
Drain
hose
Leakage
checking
Connecting area
drain hose
Leakage
checking
Содержание AM07BP NSJ
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 02A Replaces 0CTI5 01C P No MFL67502513 ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 33: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 5 Wiring Diagrams Deluxe Model AMNW07GSJL0 DM07RP NSJ ...
Страница 140: ...MULTI SINGLE Indoor unit 3 Dimensions 14 Ceiling Mounted cassette 4 way ZTNW18GQLA0 CT18R NQ0 ...
Страница 141: ...3 Dimensions 15 MULTI SINGLE Indoor unit Ceiling Mounted cassette 4 way ZTNW24GPLA0 CT24R NP0 ...