MULTI/SINGLE
Indoor unit
8. Installation
34
Wall Mounted Unit (2)
̰
Connecting the installation pipe and drain hose
1. Align the center of the pipes and sufficiently tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing.
̰
Wrap the insulation material around the connecting portion.
1. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together
with vinyl tape so that there may be no gap.
2. Set the tubing cutting line upward. Wrap the area which accommodates the rear piping housing section with vinyl
tape.
3. Bundle the piping and drain hose together by wrapping them with vinyl tape sufficient enough to cover where
they fit into the rear piping housing section. Be sure that the drain hose is located at the lowest side of the bundle.
Locating at the upper side can cause overflow from the drain pan through the inside of the unit.
CAUTION
If the drain hose is routed inside the room insulate the hose with an insulation material* so that dripping from
sweating condensation) will not damage furniture or floors.
* The feature can be changed according to type of model.
* According to product type, model line up, sales region..etc, applicability of each chassis could be different.
Chassis Cover
Right
Back side view
Tubing holder
Backwards
Left
Pipe Port
Indoor unit tubing
Flare nut Pipes
Wrench
Indoor unit tubing
Open-end wrench
(fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Insulation material
Vinyl tape(narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Gas Pipe
Liquid Pipe
Cutting Line
Cutting Line
Good Case
Bad Case
* Tubing cutting line have to be upward.
Содержание AM07BP NSJ
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 02A Replaces 0CTI5 01C P No MFL67502513 ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 33: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 5 Wiring Diagrams Deluxe Model AMNW07GSJL0 DM07RP NSJ ...
Страница 140: ...MULTI SINGLE Indoor unit 3 Dimensions 14 Ceiling Mounted cassette 4 way ZTNW18GQLA0 CT18R NQ0 ...
Страница 141: ...3 Dimensions 15 MULTI SINGLE Indoor unit Ceiling Mounted cassette 4 way ZTNW24GPLA0 CT24R NP0 ...