set wireless zone: 

The wireless zone can control the main only after setting. 

Operation program 

Voice prompt /LED state 

2 0-9(zone)          :set to indoor zone 
                              :set to outdoor zone 
                       

*

    :set to fire or 24HR zone 

                        # : set to medical zone 

And then trigger the wireless detector emit 
signal to the main. 1 DI sound will be heard and 
setting successfully.

 

Example

 

Result and remarks 

2    1                   

Sense the LX-AL8 and make it emit signal. 1 DI 
sound will be heard. So this LX-AL8 is set to No.1 
zone and is outdoor zone 

Set wireless zone attention: 

  If the zones having set need to set another type, at first you should delete the zone having set and then set to 

another type. 

 

If the coding of the zone needing set is same as the coding of zone having set, during setting 

DiDi

…”

 sound will 

be heard, and the numerical LED display the zone number Having set, the zone can not be set. Here you can 
revise its coding or delete the zone having set and then re-set). 

 

5

delete wireless zone 

Operation program 

remarks 

2 0-9(zone) 0 

Delete wireless zone 

 

6

resume deleted wireless zone 

Operation program 

remarks 

2 0-9(zone) 1 

Resume deleted wireless zone 

 

7

wireless zone time-delay setting 

Operation program 

remarks 

2 # 0-9(zone) 0

0sec

 

1

10sec

 

2

20sec

 

Set the time-delay from wireless zone is triggered 
to the main start alarm 

 

8

set wired zone 

Operation program 

remarks 

3 1-4(zone)            : set to indoor zone             

set to outdoor zone 

*

      : set to 24HR zone

 

Set the type of wired zone having 
connected with the main 
NOTE: No.1 zone is the main

s sensor.

 

 

9

delete wired zone 

Operation program 

remarks 

3 1-4(zone) 0 

Delete wired zone 

 

10

resume deleted wired zone 

Operation program 

remarks 

3 1-4(zone) 1 

Resume deleted wired zone

 

 

11

wired zone time-delay setting 

Operation program 

remarks 

3 # 1-4(zone) 0

0sec

 

1

10sec

 

2

20sec

 

Set the time-delay from wired zone is triggered to 
the main start alarm 

 

12

set remote controller

 the remote controller can control the main only after setting.

 

Operation program 

Voice prompt /LED state 

4 1-4 #   

And then press the emitting key, 1 DI sound will 
be heard and setting successfully. 

Set remote controller attention: 

  You can set 4-group remote controllers with different coding. 

Содержание LX-HS03

Страница 1: ...select the numeral key that you didn t select forestall and then select position key For example for the indoor detector select key the outdoor detector select key and then switch on the internal powe...

Страница 2: ...h on power the controller give Di sound and then the display window count down 9 8 7 1 and then give DiDi the controller enter working state Here it has been in armed state Press the disarm key on rem...

Страница 3: ...key the main stops alarming and you can monitor hearing the scene sound after DI sound you can press key to continue hearing scene sound otherwise it will automatically ring off after some time press...

Страница 4: ...time delay 20 sec Press 1 input TEL No to save press 1 to delete Press 2 input TEL No to save press 2 to delete Press 3 input TEL No to save press 3 to delete Press 4 input TEL No to save press 4 to...

Страница 5: ...er please repeat to operate this program The number is permit 15bits at most 3 delete telephone number Operation program Voice prompt LED state 1 1 4 2 DI sounds will be heard Example Result and remar...

Страница 6: ...rks 2 0 9 zone 0 Delete wireless zone 6 resume deleted wireless zone Operation program remarks 2 0 9 zone 1 Resume deleted wireless zone 7 wireless zone time delay setting Operation program remarks 2...

Страница 7: ...le robber enter please call the police 3 fire alarm or 24HR zone record example fire occur please succor 4 medical zone record please call ambulance Voice prompt LED state 1 DI sound prompt you start...

Страница 8: ...wireless zone be triggered 26 re memorize wired zone s state Operation program Voice prompt LED state 9 5 1 DI sound confirm Special attention if the main alarm immediately after counting down 9 8 7...

Страница 9: ...hat the sensor lamp work reliably With screwdriver tighten off the bottom screw and then insert a flat screw into middle slot and pull up it to open the front cover fig 1 Place the front cover with PC...

Страница 10: ...signal and the main will give 1 DI sound setting successfully Press it 3 times within 15sec When pressing it the MEDICAL LED light And the main will alarm and dial The MEDICAL LED light Wireless infr...

Страница 11: ...n emitter aims at triangle on magnetism when the battery lid is removed it will emit signal to the main 3 operate Set its coding by DIP switch Wireless setting enter set wireless zone in setting mode...

Отзывы: