Basic configure
Configure instruction:
To strengthen security, besides the
standard configure we provide, you can add other fittings. Our
fittings for your choice have: wireless smoke
alarm(LX98-RF,LX728-RF)\ siren(LX-SR)\ wireless detector(glass
detector LX-AL5, PIR detector(LX-AL6),PIR& glass
detector(LX-AL7), double detector(LX-AL11)\ wired or wireless
detector(LX-AL9)etc.
Main
’
s specification
Power: power adapter provide DC12V 1A
Standby power: DC12V (chargeable battery groups)
Working frequency: 433MHz
Receiving distance:
≥
30m(wide place)
Static current: 30mA
Alarm current: 150 mA
Alarm volume:
≥
90db
Sense angle: 120
°
Sense distance:9m.max(<24
℃
)
Installation height:2m-2.5m
Main
’
s panel instruction
1
.
AWAY: Away arm, green, Lighting indicate away arm state.
2
.
HOME: Home arm, red,Lighting indicate home arm state.
3
.
FIRE: Fire alarm LED, red,it light when smoke/gas/ CO detector is
alarming. After disarm it flash( this is alarm memory state, this
memory function will be cancelled after re-arm)
4
.
MEDICAL: Medical for help LED,yellow, it light when during medical
alarming. After disarm it flash( this is alarm memory state, this
memory function will be canalled after re-arm)
5
.
Numeric LED:When display 0-9, it indicate this zone have status
(for example: guard against theft alarming). Numeric LED displays
“
.
”
When panic alarm.
6
.
0-9
、
*
、
#
、
SET
(
function setting
)、
(
home arm
)、
(
away arm
)、
CE
(
Exit setting\return previous
menu
)
total 16 keys for system setting.
Operation function instruction
1. Switch on power, the controller give
”
Di
”
sound, and then the display window count down 9,8,7
…
1, and then give
“
DiDi
”
, the controller enter working state. Here it has been in armed state. Press the
“
disarm
”
key on remote
controller to disarm system. And then you can operate the main.
2.press
*
key
→
input operation password
(
out factory set to 0000
)
DI
…—
DI sound
→
press SET to enter setting mode.
Special attention: if the main alarm immediately after counting down 9,8,7
…
1( the wired detector-- include the
main
’
s sensor have been triggered falsely), here you need disarm the system, and then cover the detection window
of the main with opaque object(like black cloth), for other wired zones you should ensure them to not triggered.
press* key
→
input operation password
→
press
“
SET
”
→
“
9
”
→
“
5
”
re-memorize all wired zone
’
s state.
3. Set wireless fittings in setting mode, it can set continuously divisionally. The wireless fittings can control the main
only after setting successfully.
4.Wireless zone has 0-9 zones, every zone can be set to indoor/outdoor/24Hr zone/medical alarm type. The
numeric LED display wireless zone
“
0/1/2
…
9
”
5. Wired zone has 1-4 zones, every zone can be set to indoor/outdoor/24Hr zone type. The numeric LED display
wired zone
“
1./2./3./4
”
. The No.1 zone is the main
’
s sensor.
LX-HS03 main
(
chargeable battery include
)
1pcs
Power adapter
(
AC220V DC12V 1A
)
1pcs
Wireless PIR detector LX-AL8
(
battery include
)
1pcs
Wireless door magnetism LX-DM1
(
battery include
)
2pcs
Single-key remote controllerLX-FS1
(
battery include
)
1pcs
4-key remote controller LX-FS4-V3
(
battery include
)
2pcs
Phone line
1pcs
SET
CE
HOME
AWAY
FIRE
MEDICAL
MEDICAL
FIRE
AWAY
HOME
SET
CE
HOME
AWAY
FIRE
MEDICAL