4-key remote controller
LX-FS4-V3
1.specification
①
power:DC3V ( lithium battery)
②
static current:
<
1
μ
A emitting current:<8mA
③
remote control distance:
≥
30m(wide place)
2.operate
①
at first set its code. It adapts free coding. The coding method: tighten off the
base screw and open it, press and hold any emission key and then install battery,
here the LED flash indicating it is coding. The coding is confirmed when you
loosen the key.( if you find remote controllers have repeat codlings, you can
re-code according above method).
②
wireless setting: Enter
“
set remote controller
”
in setting mode, press any
emitting key to make it emit signal, and the main will give 1 DI sound, setting
successfully.
③
key function:
◇
push up the panic key, the main give panic alarm, and also it dial numbers by turns.
◇
Press arm key : Away/home arm, the corresponding HOME,AWAY LED light.
◇
Press disarm key : Cancel arm, and also can intermit alarming and dialing.
◇
Press delay arm key : the main give DI
—
DI sound, and after 60sec, DI sound will be heard again, enter armed,
AWAY LED light.
Single-key remote controller
LX-FS1
:it is designed for medical alarm.
1.specification
①
power:DC12V A23 battery
②
static current: 0
μ
A emitting current:<4mA
③
remote control distance:
≥
30m(wide place)
2.operation
①
wireless setting: Enter
“
set wireless zone
”
in setting mode and select
“
set to medical
alarm
”
, press emitting key to make it emit signal, and the main will give 1 DI sound, setting
successfully.
②
Press it 3 times within 15sec(When pressing it, the MEDICAL LED light.). And the main
will alarm and dial. The MEDICAL LED light.
Wireless infrared motion detector LX-AL8
1.specification
power:DC9V 6F22 battery detect angle:110
°
static current:30
μ
A remote control distance:
≥
30m
(
wide place
)
detect distance:12m installation height:2m
2.function
①
prevent false-alarm function: you can set sense once/twice to emit;
②
sense
、
emission LED
③
Low-battery LED: When battery energy is below 7V, the low-battery LED will flash once a
second and remind you replace battery.
3.jumper setting( see right diagram)
①
sense once to emit:
Sense once, the unit emit signal,15sec later after it emit
signal. Sense it once again, the unit emit signal again;
②
sense twice to emit:
Sense twice, the unit emit signal, 15sec later after
it emit signal. Sense it twice again, the unit emit
signal again; this setting enhance its preventing
false-alarm and preventing-pet function
.
4.operate and install
◇
switch on 9V battery, after 60sec the unit enter working state;
◇
set its coding by DIP switch;
◇
wireless setting: Enter
“
set wireless zone
”
in setting mode, sway your hand in front of the detecting window to
make it emit signal, and the main will give 1 DI sound, setting successfully.
◇
we suggest it should be installed in dypass, living room, reside room etc area, and install it on high place. Its
AUTO
DIP switch
Sense LED
PIR
Jumper
A
U
T
O
/
1
A
U
T
O
/
1
1
Emit LED
Sense
once to
emit
Sense
twice to
emit
Low-battery LED
panic
disarm
delay arm
arm
push up